Recent neuroimaging and electrophysiological studies have suggested substantial short-term plasticity in the topographic maps of the primary motor cortex (M1). However, previous methods lack the temporal resolution to detect rapid modulation of these maps, particularly in naturalistic conditions. To address this limitation, we previously developed a rapid stimulation mapping procedure with implanted cortical surface electrodes.
View Article and Find Full Text PDFAmong the large family of transition metal dichalcogenides, recently ReS has stood out due to its nearly layer-independent optoelectronic and physicochemical properties related to its 1T distorted octahedral structure. This structure leads to strong in-plane anisotropy, and the presence of active sites at its surface makes ReS interesting for gas sensing and catalysts applications. However, current fabrication methods use chemical or physical vapor deposition (CVD or PVD) processes that are costly, time-consuming and complex, therefore limiting its large-scale production and exploitation.
View Article and Find Full Text PDFObjective: Motor map has been widely used as an indicator of motor skills and learning, cortical injury, plasticity, and functional recovery. Cortical stimulation mapping using epidural electrodes is recently adopted for animal studies. However, several technical limitations still remain.
View Article and Find Full Text PDFACS Appl Mater Interfaces
February 2018
Nitrogen-doped single-walled carbon nanohorns (N-SWCNHs) are porous carbon material characterized by unique horn-shape structures with high surface areas and good conductivity. Moreover, they can be mass-produced (tons/year) using a novel proprietary process technology making them an attractive material for various industrial applications. One of the applications is the encapsulation of sulfur, which turns them as promising conductive host materials for lithium-sulfur batteries.
View Article and Find Full Text PDFCortical stimulation mapping is a valuable tool to test the functional organization of the motor cortex in both basic neurophysiology (e.g., elucidating the process of motor plasticity) and clinical practice (e.
View Article and Find Full Text PDFKey Points: The cortical mechanisms of grasping have been extensively studied in macaques and humans; here, we investigated whether common marmosets could rely on similar mechanisms despite strong differences in hand morphology and grip diversity. We recorded electrocorticographic activity over the sensorimotor cortex of two common marmosets during the execution of different grip types, which allowed us to study cortical activity (power spectrum) and physiologically inferred connectivity (phase-slope index). Analyses were performed in beta (16-35 Hz) and gamma (75-100 Hz) frequency bands and our results showed that beta power varied depending on grip type, whereas gamma power displayed clear epoch-related modulation.
View Article and Find Full Text PDFThe development of large-scale production methods of two-dimensional (2D) crystals, with on-demand control of the area and thickness, is mandatory to fulfill the potential applications of such materials for photovoltaics. Inverted bulk heterojunction (BHJ) organic solar cell (OSC), which exploits a polymer-fullerene binary blend as the active material, is one potentially important application area for 2D crystals. A large ongoing effort is indeed currently devoted to the introduction of 2D crystals in the binary blend to improve the charge transport properties.
View Article and Find Full Text PDFHigh-density surface microelectrodes for electrocorticography (ECoG) have become more common in recent years for recording electrical signals from the cortex. With an acceptable invasiveness/signal fidelity trade-off and high spatial resolution, micro-ECoG is a promising tool to resolve fine task-related spatial-temporal dynamics. However, volume conduction - not a negligible phenomenon - is likely to frustrate efforts to obtain reliable and resolved signals from a sub-millimeter electrode array.
View Article and Find Full Text PDFACS Appl Mater Interfaces
February 2016
LiMnPO4 is an attractive cathode material for the next-generation high power Li-ion batteries, due to its high theoretical specific capacity (170 mA h g(-1)) and working voltage (4.1 V vs Li(+)/Li). However, two main drawbacks prevent the practical use of LiMnPO4: its low electronic conductivity and the limited lithium diffusion rate, which are responsible for the poor rate capability of the cathode.
View Article and Find Full Text PDFACS Appl Mater Interfaces
July 2015
Simple fabrication, high power-to-weight and power-to-volume ratios, and the ability to operate in open air at low voltage make the ionic electroactive polymer actuators highly attractive for haptic applications. Whenever a direct tactile stimulation of the skin is involved, electrical and chemical insulation as well as a long-term stability of the actuator are required. Because of its inherent physicochemical properties such as high dielectric strength, resistance to solvents, and biological inactivity, Parylene C meets the requirements for making biocompatible actuators.
View Article and Find Full Text PDFIEEE Trans Biomed Circuits Syst
February 2015
One of the most difficult tasks for the surgeon during the removal of low-grade gliomas is to identify as precisely as possible the borders between functional and non-functional brain tissue with the aim of obtaining the maximal possible resection which allows to the patient the longer survival. For this purpose, systems for acute extracellular recordings of single neuron and multi-unit activity are considered promising. Here we describe a system to be used with 16 microelectrodes arrays that consists of an autoclavable headstage, a built-in inserter for precise electrode positioning and a system that measures and controls the pressure exerted by the headstage on the brain with a twofold purpose: to increase recording stability and to avoid disturbance of local perfusion which would cause a degradation of the quality of the recording and, eventually, local ischemia.
View Article and Find Full Text PDFLiFePO4 has been intensively investigated as a cathode material in Li-ion batteries, as it can in principle enable the development of high power electrodes. LiFePO4, on the other hand, is inherently "plagued" by poor electronic and ionic conductivity. While the problems with low electron conductivity are partially solved by carbon coating and further by doping or by downsizing the active particles to nanoscale dimensions, poor ionic conductivity is still an issue.
View Article and Find Full Text PDFIEEE Trans Neural Syst Rehabil Eng
May 2015
Electrocorticography (ECoG) is becoming a common tool for clinical applications, such as preparing patients for epilepsy surgery or localizing tumor boundaries, as it successfully balances invasiveness and information quality. Clinical ECoG arrays use millimeter-scale electrodes and centimeter-scale pitch and cannot precisely map neural activity. Higher-resolution electrodes are of interest for both current clinical applications, providing access to more precise neural activity localization and novel applications, such as neural prosthetics, where current information density and spatial resolution is insufficient to suitably decode signals for a chronic brain-machine interface.
View Article and Find Full Text PDFFinding the most appropriate technology for building electrodes to be used for long term implants in humans is a challenging issue. What are the most appropriate technologies? How could one achieve robustness, stability, compatibility, efficacy, and versatility, for both recording and stimulation? There are no easy answers to these questions as even the most fundamental and apparently obvious factors to be taken into account, such as the necessary mechanical, electrical and biological properties, and their interplay, are under debate. We present here our approach along three fundamental parallel pathways: we reduced electrode invasiveness and size without impairing signal-to-noise ratio, we increased electrode active surface area by depositing nanostructured materials, and we protected the brain from direct contact with the electrode without compromising performance.
View Article and Find Full Text PDFIn phospho-olivine type structures with mixed cations (LiM1M2PO4), the octahedral M1 and M2 sites that dictate the degree of intersites order/disorder play a key role in determining their electrochemical redox potentials. In the case of LiFexMn1-xPO4, for example, in micrometer-sized particles synthesized via hydrothermal route, two separate redox centers corresponding to Fe(2+)/Fe(3+) (3.5 V vs Li/Li(+)) and Mn(2+)/Mn(3+) (4.
View Article and Find Full Text PDFThe ongoing interest in densely packed miniaturized electrode arrays for high-resolution epicortical recordings has induced many researchers to explore the use of nanomaterial coatings to reduce electrode impedance while increasing signal-to-noise ratio and charge injection capability. Although these materials are very effective, their use in clinical practice is strongly inhibited by concerns about the potential risks derived from the use of nanomaterials in direct contact with the human brain. In this work we propose a novel approach to safely couple nanocoated electrodes to the brain surface by encapsulating them with a biocompatible hydrogel.
View Article and Find Full Text PDFExtracellular metal microelectrodes are widely used to record single neuron activity in vivo. However, their signal-to-noise ratio (SNR) is often far from optimal due to their high impedance value. It has been recently reported that carbon nanotube (CNT) coatings may decrease microelectrode impedance, thus improving their performance.
View Article and Find Full Text PDFWe report for the first time how coatings made by directly growing carbon nanotubes (CNTs) on the tip of neural microelectrodes outperform others made by electrodeposited CNT composites. Not only do they reduce microelectrode impedance but they also are able to inject high currents without degradation and are stable in time. These results suggest that they are excellent candidates for chronic applications especially when both neural recording and stimulation have to be performed by the same microelectrode.
View Article and Find Full Text PDF