Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Patient-derived tumor organoids (PDTOs) are promising 3D disease models for developing personalized treatment methods. However, conventional technologies for making PDTOs have limitations such as batch-to-batch variation and low throughput. Droplet microfluidics (DM), which utilizes uniform droplets generated in microchannels, has demonstrated potential for creating organoids due to its high-throughput and controllable parameters. However, most existing DM devices require a high initial cell count, on the order of 10, which is difficult to acquire with biopsy samples. A novel step-stone strategy is to encapsulate preformed spheroids in hydrogel droplets, creating a microenvironment supporting their future growth into organoids or for immediate analysis. While a similar strategy has been reported, the viability and uniformity of spheroids after encapsulation, which are important for continuous growth into organoids, were not examined. We present a DM device featuring a double-cross geometry chip to encapsulate preformed spheroids into hydrogel microparticles (HMPs) with a very low initial cell count (order of 10) and ensuring high viability and uniformity of the spheroids in the recovered cross-linked HMPs. The preformed spheroids, 100-200 μm in diameter, were successfully encapsulated in well-defined HMPs. With contrasting viscosity hydrogels, a hydrodynamic focusing stream was created to leverage spheroids into their own droplets. Preformed spheroid encapsulation efficiency was affected by the width of the focusing stream and the quantity of spheroids at the inlet, with the best results reaching about 75% total encapsulation and 54% single spheroid encapsulation. Spheroid-laden HMPs were collected and cross-linked off-chip, where spheroids could continue to grow. The encapsulated spheroids maintained above 80% viability over 5 days of culture and retained uniformity with less than a 4% difference in diameter variation compared to pre-encapsulated spheroids. Ultimately, we demonstrated that preformed spheroid encapsulation using DM was a robust way to encapsulate a low sample size while maintaining viability and uniformity.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsbiomaterials.5c01015DOI Listing

Publication Analysis

Top Keywords

preformed spheroids
16
spheroids hydrogel
12
viability uniformity
12
spheroid encapsulation
12
spheroids
11
initial cell
8
cell count
8
count order
8
encapsulate preformed
8
growth organoids
8

Similar Publications

Patient-derived tumor organoids (PDTOs) are promising 3D disease models for developing personalized treatment methods. However, conventional technologies for making PDTOs have limitations such as batch-to-batch variation and low throughput. Droplet microfluidics (DM), which utilizes uniform droplets generated in microchannels, has demonstrated potential for creating organoids due to its high-throughput and controllable parameters.

View Article and Find Full Text PDF

Purified adipose tissue-derived extracellular vesicles facilitate adipose organoid vascularization through coordinating adipogenesis and angiogenesis.

Biofabrication

February 2025

Department of Cleft Lip and Palate, Plastic Surgery Hospital, Chinese Academy of Medical Sciences, Peking Union Medical College, No.33 Badachu Road, Shijingshan District, Beijing 100144, People's Republic of China.

One of the major challenges in the way of better fabricating vascularized adipose organoids is the destructive effect of adipogenic differentiation on preformed vasculature, which probably stems from the discrepancy between thephysiological microenvironment and theculture conditions. As an intrinsic component of adipose tissue (AT), adipose tissue-derived extracellular vesicles (AT-EVs) have demonstrated both adipogenic and angiogenic ability in recent studies. However, whether AT-EVs could be employed to coordinate the angiogenesis and adipogenesis in the vascularization of adipose organoids remains largely unexplored.

View Article and Find Full Text PDF

The e-Flower: A hydrogel-actuated 3D MEA for brain spheroid electrophysiology.

Sci Adv

October 2024

Laboratory for Soft Bioelectronic Interfaces, Neuro-X Institute, École Polytechnique Fédérale de Lausanne (EPFL), Geneva, Switzerland.

Traditional microelectrode arrays (MEAs) are limited to measuring electrophysiological activity in two dimensions, failing to capture the complexity of three-dimensional (3D) tissues such as neural organoids and spheroids. Here, we introduce a flower-shaped MEA (e-Flower) that can envelop submillimeter brain spheroids following actuation by the sole addition of the cell culture medium. Inspired by soft microgrippers, its actuation mechanism leverages the swelling properties of a polyacrylic acid hydrogel grafted to a polyimide substrate hosting the electrical interconnects.

View Article and Find Full Text PDF

Triple negative breast cancer (TNBC) has long been a challenging disease owing to its high aggressive behaviour, poor prognosis and its limited treatment options. The growing demand of new therapeutics against TNBC enables us to examine the therapeutic efficiency of an emerging class of anticancer compounds, azapodophyllotoxin derivative (HTDQ), a nitrogen analogue of podophyllotoxin, using different biochemical, spectroscopic and computational approaches. The anticancer activities of HTDQ are studied by performing MTT assay in a dose depended manner on Triple negative breast cancer cells using MDA-MB-468 and MDA-MB-231 cell lines with IC value 937 nM and 1.

View Article and Find Full Text PDF

Cancer treatment has transformed in recent years, with the introduction of immunotherapy providing substantial improvements in prognoses for certain cancers. However, traditional small molecule chemotherapeutics remain the major frontline of defence, and improving their delivery to solid tumors is of utmost importance for improving potency and reducing side effects. Here, length-controlled one-dimensional seed nanofibers ( 25 nm, = 1.

View Article and Find Full Text PDF