Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Occupational heat stress recommendations aim to achieve thermal equilibrium and keep core temperature (T) below 38.0°C. We assessed the recommended alert limit curves when: (1) work-rest ratios are adjusted based on wet-bulb globe temperature (WBGT) at a fixed rate of metabolic heat production (H) and (2) H is adjusted based on WBGT at a fixed work-rest ratio. We tested the hypothesis that adhering to occupational heat stress recommendations results in thermal equilibrium and prevents T from exceeding 38.0°C.

Methods: Unacclimated adults completed 4-hour exposures at a fixed WBGT, H, and work-rest ratio. There were six iterations of compliant trials (n = 70 observations; A: 24.1°C, 431 W, 60:0 min; B: 26.6°C, 461 W, 45:15 min; C: 28.4°C, 462 W, 30:30 min; D: 29.7, 453 W, 15:45 min; E: 27.3°C, 412 W, 30:30 min; F: 31.6°C, 290 W, 30:30 min) and two iterations of noncompliant trials (n = 24 observations; G: 31.6°C, 413 W, 30:30 min; H: 36.1°C, 453 W, 15:45 min).

Results: Mean and peak T across the compliant trials were 37.6°C ± 0.3°C and 37.9°C ± 0.3°C. Thus, 65/70 (93%) and 44/70 (63%) trials did not exceed a mean or peak core T of 38.0°C. Mean and peak T across the noncompliant trials exceeded 38.0°C in all trials. The rate of heat gain differed between compliant and noncompliant trials (0.08°C ± 0.07°C/h vs. 0.41°C ± 0.34°C/h; p < 0.0001) but on average thermal equilibrium was < 0.1°C/h in the compliant trials.

Conclusion: Compliance with the occupational heat stress recommendations resulted in thermal equilibrium and mitigated the development of excessive heat strain.

Trial Registration: ClinicalTrials.gov: NCT04767347.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ajim.70022DOI Listing

Publication Analysis

Top Keywords

occupational heat
12
noncompliant trials
12
recommended alert
8
alert limit
8
limit curves
8
heat stress
8
stress recommendations
8
thermal equilibrium
8
adjusted based
8
wbgt fixed
8

Similar Publications

Background: Occupational heat stress recommendations aim to achieve thermal equilibrium and keep core temperature (T) below 38.0°C. We assessed the recommended alert limit curves when: (1) work-rest ratios are adjusted based on wet-bulb globe temperature (WBGT) at a fixed rate of metabolic heat production (H) and (2) H is adjusted based on WBGT at a fixed work-rest ratio.

View Article and Find Full Text PDF

High Environmental Heat Exposure Is a Risk Factor for Acute Kidney Injury and Chronic Kidney Disease.

Semin Nephrol

September 2025

University of Alabama at Birmingham, Department of Medicine, Division of Nephrology, Section of Cardio-Renal Physiology and Medicine, Birmingham, AL. Electronic address:

Chronic kidney disease of unknown etiology has been reported in Mesoamerican regions and other parts of the world, with increasing evidence pointing to heat stress as a central contributing factor. The incidence of acute kidney injury appears to correlate strongly with heat exposure, as demonstrated in both human and animal studies. The underlying mechanisms of heat-induced kidney injury are likely multifactorial, involving hemodynamic changes, immune responses, and possibly coagulopathies.

View Article and Find Full Text PDF

Impact of Summer Heat on male Children's Physiological Responses During Football Training.

Environ Res

September 2025

Institute and Clinic for Occupational, Social and Environmental Medicine, University Hospital, LMU Munich, 80336 Munich, Germany. Electronic address:

Background: As summer temperatures rise due to climate change, the Pediatrics Society calls for more research on children's core body temperature. This study aims to analyze these concerns by investigating the specific effects of heat exposure on children's physiological parameters such as body temperature during football training.

Methods: This case-crossover study investigated the effects of heat on several physiological parameters (e.

View Article and Find Full Text PDF

Radioisotope Thermoelectric Generators (RTGs) are devices that convert heat from radioactive decay into electrical energy and are used in remote locations due to their low maintenance requirements. Various types of RTGs were produced with sources containing large amounts of Strontium-90, which require multiple layers of shielding materials. However, the lack of control and the ease of access to the source increase the biological risk in the event of a breach of the device.

View Article and Find Full Text PDF

Rationale: Industry guidelines recommend work-rest schedules to prevent unsafe core temperature elevations (> 38.0°C or > Δ1.0°C above baseline resting) in an "average" worker exposed to occupational heat stress.

View Article and Find Full Text PDF