Differentiating electron diffuse scattering via 4D-STEM spatial fluctuation and correlation analysis in complex FCC alloys.

Ultramicroscopy

Department of Materials Science and Engineering, University of Illinois at Urbana-Champaign, 1304W. Green Street, Urbana 61801, IL, USA; Materials Research Laboratory, University of Illinois at Urbana-Champaign, 104 South Goodwin Avenue, Urbana 61801, IL, USA. Electronic address:

Published: August 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Complex face-centered-cubic (FCC) alloys frequently display chemical short-range ordering (CSRO), which can be detected through the analysis of diffuse scattering. However, the interpretation of diffuse scattering is complicated by the presence of defects and thermal diffuse scattering, making it extremely challenging to distinguish CSRO using conventional scattering techniques. This complexity has sparked intense debates regarding the origin of specific diffuse-scattering signals, such as those observed at 1/3{422} and 1/2{311} positions. To address this challenge, we introduce the method of spatial fluctuation and correlation (FluCor) analysis of local diffuse scattering captured using Four-Dimensional Scanning Transmission Electron Microscopy (4D-STEM). We demonstrate our methodology using a solution-treated (CrCoNi)AlTiNb medium-entropy alloy (MEA) and show that the FluCor analysis can differentiate diffuse scattering of different origins. The results reveal two sets of overlapping diffuse-scattering signals at the 1/3{422} and 1/2{311} positions in the studied MEA and link both to non-CSRO origins. Specifically, the heterogeneous-domain diffuse-scattering signals are attributed to nanoscale planar defects, while the homogeneous diffuse-scattering of the matrix is best explained by thermal-diffuse scattering. The principles underlying our fluctuation and correlation analysis of diffuse scattering are general and broadly applicable to order-disordered crystals, including various complex alloy systems. This versatility promises to yield valuable insights into the interplay between microstructural characteristics and CSRO behavior in a wide range of materials, potentially resolving long-standing debates in the field.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultramic.2025.114228DOI Listing

Publication Analysis

Top Keywords

diffuse scattering
28
fluctuation correlation
12
diffuse-scattering signals
12
scattering
9
spatial fluctuation
8
correlation analysis
8
fcc alloys
8
analysis diffuse
8
1/3{422} 1/2{311}
8
1/2{311} positions
8

Similar Publications

Multi-compartment diffusion-relaxation MR signal representation in the spherical 3D-SHORE basis.

Comput Biol Med

September 2025

Laboratorio de Procesado de Imagen (LPI), ETSI Telecomunicación, Universidad de Valladolid, Valladolid, Spain. Electronic address:

Modelling the diffusion-relaxation magnetic resonance (MR) signal obtained from multi-parametric sequences has recently gained immense interest in the community due to new techniques significantly reducing data acquisition time. A preferred approach for examining the diffusion-relaxation MR data is to follow the continuum modelling principle that employs kernels to represent the tissue features, such as the relaxations or diffusion properties. However, constructing reasonable dictionaries with predefined signal components depends on the sampling density of model parameter space, thus leading to a geometrical increase in the number of atoms per extra tissue parameter considered in the model.

View Article and Find Full Text PDF

Differentiating electron diffuse scattering via 4D-STEM spatial fluctuation and correlation analysis in complex FCC alloys.

Ultramicroscopy

August 2025

Department of Materials Science and Engineering, University of Illinois at Urbana-Champaign, 1304W. Green Street, Urbana 61801, IL, USA; Materials Research Laboratory, University of Illinois at Urbana-Champaign, 104 South Goodwin Avenue, Urbana 61801, IL, USA. Electronic address:

Complex face-centered-cubic (FCC) alloys frequently display chemical short-range ordering (CSRO), which can be detected through the analysis of diffuse scattering. However, the interpretation of diffuse scattering is complicated by the presence of defects and thermal diffuse scattering, making it extremely challenging to distinguish CSRO using conventional scattering techniques. This complexity has sparked intense debates regarding the origin of specific diffuse-scattering signals, such as those observed at 1/3{422} and 1/2{311} positions.

View Article and Find Full Text PDF

This work reports the nanoscale micellar formation in single and mixed surfactant systems by combining an amphiphilic graft copolymer, Soluplus® (primary surfactant), blended with other polyoxyethylene (POE)-based nonionic surfactants such as Kolliphor® HS15, Kolliphor® EL, Tween-80, TPGS®, and Pluronics® P123 in an aqueous solution environment. The solution behaviour of these surfactants as a single system were analyzed in a wide range of surfactant concentrations and temperatures. Rheological measurements revealed distinct solution behaviour in the case of Soluplus®, ranging from low-viscosity () and fluid-like behavior at ≤20% w/v to a highly viscous state at ≥90% w/v, where the loss modulus ('') exceeded the storage modulus (').

View Article and Find Full Text PDF

A 79-year-old female diagnosed with myelodysplastic syndrome (MDS) and germline GATA2 mutation, on compassionate cobimetinib, was admitted with subacute cough and dyspnea. Chest imaging demonstrated a new, large, left hilar mass and consolidation with scattered diffuse mediastinal, supraclavicular, and hilar lymphadenopathy. A core biopsy of the right supraclavicular lymph node was performed.

View Article and Find Full Text PDF

Purpose: To report a case of Epstein-Barr virus (EBV) corneal endotheliitis and uveitis in a patient diagnosed with extranodal natural killer/T-cell lymphoma (ENKTL).

Methods: This is a case report performed at a tertiary care center in the Republic of Korea.

Results: A 64-year-old man presented with decreased vision in his right eye that had persisted for 4 days.

View Article and Find Full Text PDF