98%
921
2 minutes
20
Flexible sensors integrating motion detection and tactile perception capabilities demonstrate significant potential in aerospace biomechanics and medical rehabilitation. Here, we report a biomimetic inflatable chamber sensor that synergistically integrates pneumatic-auxiliary and electronic sensing for elbow joint health monitoring. The device architecture combines multiwalled carbon nanotube-reinforced silicone composites with embedded electrode arrays integrated within the inner lining of inflatable chambers, achieving high sensitivity while maintaining signal stability under electromagnetic interference. Dual-mode operation enables textile-integrated elbow joint kinematics mapping in passive mode and pneumatically tunable collision detection with pressure-adaptive safety response. Experimental validation demonstrated the diagnostic methodology's optimal efficiency and accuracy, highlighting its potential as elbow joint injury rehabilitation training equipment. This pneumotronic design paradigm bridges soft robotics and wearable electronics, providing positive impacts for joint diagnosis and rehabilitation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acsami.5c13471 | DOI Listing |
Sports Biomech
September 2025
Centre for Interdisciplinary Research in Rehabilitation, Lethbridge-Layton-Mackay Rehabilitation Centre, and the School of Physical and Occupational Therapy, McGill University, Montreal, QC, Canada.
The objective of this study was to compare joint angles and spatiotemporal variables between male and female ice hockey players during skating slap shots. Thirty-nine collegiate players (25 men, 14 women) participated. Kinematic data were collected using a Xsens 17-inertial measurement system.
View Article and Find Full Text PDFOrthop Rev (Pavia)
September 2025
Introduction/background: Complex articular fractures around the knee in the elderly patient present an ongoing challenge regarding optimal treatment. While extensive research has evaluated immediate arthroplasty following fracture of the proximal femur, distal femur, proximal humerus, and elbow, relatively little focus has been given to immediate arthroplasty following complex tibia plateau fractures.
Methods: As seen with many other fractures, arthroplasty can shorten recovery and hospital stay and allow early weight-bearing with improved mobility while minimizing complications and possible future conversion arthroplasty cost.
J Surg Case Rep
September 2025
Department of Orthopaedics and Sports Medicine, University at Buffalo, 462 Grider Street, Buffalo, NY 14215, United States.
An 8-year-old girl fell onto her outstretched arm, sustaining proximal ulna and radial neck fractures. After closed reduction and casting in the emergency department, radiographs showed improved alignment but limited bony detail. A CT scan performed 3 days later demonstrated 18° apex-medial angulation of the radial neck, slight radiocapitellar subluxation, and subtle calcification near the trochlear notch, concerning intra-articular injury.
View Article and Find Full Text PDFCroat Med J
August 2025
Damjan Dimnjaković, Zagreb University Hospital Center, Department of Orthopaedic Surgery, Šalata 7, 10000 Zagreb, Croatia,
Aim: To assess the optimal fusion angle of the elbow to accommodate the activities of daily living.
Methods: The study enrolled 30 healthy adult volunteers (mean age 24 years), who performed 29 activities with an elbow brace fixed at various flexion angles (30°, 50°, 70°, 90°, 110°, 120°). The activities were divided into three groups: the activities of daily living, personal care and hygiene, and modern activities of daily living.
Bone Jt Open
September 2025
School of Medicine, University of Nottingham, Nottingham, UK.
Aims: The number of hip fractures is increasing, with significant mortality and morbidity, particularly among frail and comorbid patients. Enhanced recovery after surgery (ERAS) pathways have proven effective in elective orthopaedics, but this has not been investigated in people with hip fractures. This study aimed to identify current perioperative practice and develop a cohesive ERAS pathway tailored for hip fracture patients, to standardize and optimize care.
View Article and Find Full Text PDF