New total knee replacement designs aim to improve patient outcomes through restoration of normal knee joint movements. This study uses in vivo fluoroscopic analysis to quantify the kinematic characteristics of the Physica KR system. Twenty-one patients underwent kinematic fluoroscopic analysis 1 year following implantation of the Physica KR knee using three defined activities (step-up, kneel, and lunge). Assessments were made of initial rollback, maximum flexion, axial rotation, anteroposterior (AP) translation, and the presence or absence of condylar lift-off. A mean maximum passive flexion of 115.8 degrees (standard deviation ± 10.8) was achieved. All joints were congruent throughout range of movement in all three activities. During the step-up activity, the medial femoral condyle exhibited some initial rollback, the lateral condyle moved slightly posteriorly during initial flexion, then back toward its initial alignment with increased flexion. The combined effect produced tibial internal rotation of approximately 5 degrees during the first 90 degrees of flexion with a smooth progression toward slight varus alignment in maximal flexion, with minimal condylar lift-off. During maximal kneeling, both the medial and lateral femoral condyle contact points were just posterior to the AP midline and lift-off of both condyles was noted. During maximal lunge, the medial contact point was slightly anterior to the AP midpoint, with the lateral contact point slightly posterior, resulting in tibial internal rotation. There was no appreciable lift-off of the lateral condyle, although medial condylar lift-off increased from mid-flexion. These in vivo data demonstrate congruent kinematics throughout range of movement, with some initial femoral rollback during early flexion. Our study has shown that the Physica KR knee implant behaved similarly to other established cruciate-retaining implants.

Download full-text PDF

Source
http://dx.doi.org/10.1055/a-2684-8816DOI Listing

Publication Analysis

Top Keywords

condylar lift-off
12
total knee
8
knee replacement
8
fluoroscopic analysis
8
physica knee
8
activities step-up
8
initial rollback
8
range movement
8
femoral condyle
8
lateral condyle
8

Similar Publications

New total knee replacement designs aim to improve patient outcomes through restoration of normal knee joint movements. This study uses in vivo fluoroscopic analysis to quantify the kinematic characteristics of the Physica KR system. Twenty-one patients underwent kinematic fluoroscopic analysis 1 year following implantation of the Physica KR knee using three defined activities (step-up, kneel, and lunge).

View Article and Find Full Text PDF

Fixation of distal femoral fractures is often challenging due to the fracture configuration and associated poor bone quality. Dual plating (lateral and medial) has become an acceptable option to provide improved stability versus a single plate fixation. Though there are several commercially available anatomically designed plates for the lateral femoral condyle, there is no anatomic plate available in UK specifically for medial fixation of distal femur fractures.

View Article and Find Full Text PDF

Background: Posterior-stabilized total knee arthroplasty (TKA) with gradually variable radii (G-curve) femoral condylar geometry is now available. It is believed that a G-curve design would lead to more mid-flexion stability leading to reduced incidence of paradoxical anterior slide. The objective of this study was to assess the in vivo kinematics for subjects implanted with this type of TKA under various conditions of daily living.

View Article and Find Full Text PDF

Background: Loss of contact between the femoral and tibial implants following total knee arthroplasty (TKA) has been related to accelerated polyethylene wear and other complications. Two methods have been used to detect loss of contact in single-plane fluoroscopy, the condylar lift-off method and the separation method. The objectives were to assess the ability of each method to detect loss of contact.

View Article and Find Full Text PDF

Background: The purpose of our study was to identify factors affecting posterior cruciate ligament (PCL) tightness during cruciate-retaining total knee arthroplasty.

Methods: A total of 225 varus osteoarthritic knees that underwent cruciate-retaining total knee arthroplasty were included in this study. When the flexion gap was tighter than the extension gap after all bone resection and the lift-off sign was positive during surgery, the PCL was released.