A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Dissolving microdroplet electroanalysis enables attomolar-level detection. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Trace detection is critical for identifying chemicals that would otherwise remain undetectable. While analytical techniques, such as spectroscopy, spectrometry, and electrochemical sensors, are effective at detecting low concentrations, achieving attomolar sensitivity remains a significant challenge. Here, we present an electroanalytical approach that leverages partitioning kinetics to detect attomolar concentrations of redox-active analytes. Using (Cp*)Fe as a model system, we demonstrate trace-level detection by facilitating the transfer of (Cp*)Fe from the bulk aqueous phase into 1,2-dichloroethane (DCE) microdroplets positioned atop a gold microelectrode (radius ∼6.25 μm). This partitioning arises from the greater solubility of (Cp*)Fe in DCE relative to its limited solubility in water, enriching the analyte concentration near the electrode as the microdroplets slowly dissolve into the aqueous phase. Additionally, we explored the role of oxygen in enhancing the electrochemical response: oxygen removal hindered detection at 1 aM, while oxygen saturation significantly amplified the redox peak signal. These findings underscore oxygen's role, which is likely a bimolecular reaction between oxygen and (Cp*)Fe in signal amplification. An EC' catalytic mechanism likely amplifies the electrochemical signal of (Cp*)Fe when the droplet is sufficiently small for feedback to occur, enabling attomolar detection of (Cp*)Fe. This study introduces a partitioning-based electroanalytical strategy taking advantage of an an EC' catalytic mechanism for ultra-low detection limits, offering promising applications in trace chemical analysis and advanced sensor technologies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12401217PMC
http://dx.doi.org/10.1039/d5an00795jDOI Listing

Publication Analysis

Top Keywords

aqueous phase
8
ec' catalytic
8
catalytic mechanism
8
detection
6
cp*fe
6
dissolving microdroplet
4
microdroplet electroanalysis
4
electroanalysis enables
4
enables attomolar-level
4
attomolar-level detection
4

Similar Publications