Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Trace detection is critical for identifying chemicals that would otherwise remain undetectable. While analytical techniques, such as spectroscopy, spectrometry, and electrochemical sensors, are effective at detecting low concentrations, achieving attomolar sensitivity remains a significant challenge. Here, we present an electroanalytical approach that leverages partitioning kinetics to detect attomolar concentrations of redox-active analytes. Using (Cp*)Fe as a model system, we demonstrate trace-level detection by facilitating the transfer of (Cp*)Fe from the bulk aqueous phase into 1,2-dichloroethane (DCE) microdroplets positioned atop a gold microelectrode (radius ∼6.25 μm). This partitioning arises from the greater solubility of (Cp*)Fe in DCE relative to its limited solubility in water, enriching the analyte concentration near the electrode as the microdroplets slowly dissolve into the aqueous phase. Additionally, we explored the role of oxygen in enhancing the electrochemical response: oxygen removal hindered detection at 1 aM, while oxygen saturation significantly amplified the redox peak signal. These findings underscore oxygen's role, which is likely a bimolecular reaction between oxygen and (Cp*)Fe in signal amplification. An EC' catalytic mechanism likely amplifies the electrochemical signal of (Cp*)Fe when the droplet is sufficiently small for feedback to occur, enabling attomolar detection of (Cp*)Fe. This study introduces a partitioning-based electroanalytical strategy taking advantage of an an EC' catalytic mechanism for ultra-low detection limits, offering promising applications in trace chemical analysis and advanced sensor technologies.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12401217 | PMC |
http://dx.doi.org/10.1039/d5an00795j | DOI Listing |