98%
921
2 minutes
20
Background: The association of outcomes with initial clip selection has not been investigated in patients undergoing transcatheter edge-to-edge repair with the MitraClip G4.
Methods: We analyzed 2257 patients receiving the MitraClip G4 according to the initial clip type: short (NT/NTW) versus long (XT/XTW) and narrow (NT/XT) versus wide (NTW/XTW). We performed a propensity-matched analysis of baseline anatomical features in patients with primary and secondary mitral regurgitation (MR).
Results: The proportions of the initial clip types were as follows: NT, 18.9%; NTW, 41.7%; XT, 5.1%; and XTW, 34.3%. The proportions of the MR severity ≤1+ at discharge and 1 year were not significantly different among the 4 clip types. The incidence of death or heart failure hospitalization was not significantly different between the initial long and short clip groups and between the initial wide and narrow clip groups. After propensity matching, in patients with primary MR, long clips were significantly associated with a greater MR reduction (2.87±0.89 versus 2.62±0.99, =0.04) and a higher proportion of the MR severity ≤1+ at 1 year (68.2% versus 48.6%, =0.04) than short clips. In patients with secondary MR, long or wide clips had a similar MR severity at discharge and 1 year as short or narrow clips.
Conclusions: Residual MR severity and outcomes were not different regardless of the initial clip type, indicating the optimal clip selection in the real-world settings with the MitraClip G4. In patients with primary MR, greater and more durable MR reduction may be expected by using the initial long clips.
Registration: URL: https://www.umin.ac.jp/ctr/; Unique identifier: UMIN-ID: UMIN000023653.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1161/JAHA.125.041907 | DOI Listing |
Surg Endosc
September 2025
The Griffin Institute, London, UK.
Background: Robotic surgery has witnessed rapid growth and development, with a concomitant training requirement. However, educational methods can vary, for example, industry or clinician led. This can result in heterogeneous training.
View Article and Find Full Text PDFFront Cardiovasc Med
August 2025
Department of Cardiovascular Surgery, University Heart Center Hamburg, Hamburg, Germany.
Background: In patients with atrial fibrillation (AF) undergoing coronary artery bypass grafting (CABG) or aortic valve replacement (AVR), many surgeons are reluctant to open the left atrium for surgical ablation. However, especially in those with persistent AF, a box lesion isolating the entire posterior left atrial wall may be beneficial. Here, we describe our initial experience with a novel closed atrium bipolar radio-frequency left atrial box ablation technique.
View Article and Find Full Text PDFAortoesophageal fistula (AEF) is a rare but life-threatening condition. Initial management typically includes thoracic endovascular aortic repair (TEVAR) or aortic graft replacement to achieve hemostasis, followed by esophagectomy with aortic graft replacement and greater omentum wrapping to eliminate the source of infection. We report a case of successful endoscopic closure of a chronic esophageal fistula secondary to AEF.
View Article and Find Full Text PDFInt J Med Robot
October 2025
Department of Biomedical Engineering, Dongguk University, Goyang, South Korea.
Background: Laparoscopic robotic surgery requires intraoperative tool replacement owing to the limited number of surgical tools that can be used simultaneously. Currently, this process is performed by a surgical assistant. However, automatic tool replacement is essential for surgeons when operating alone.
View Article and Find Full Text PDFAsian J Endosc Surg
September 2025
Department of Thoracic Surgery, Kyoto City Hospital, Kyoto, Japan.
Robot-assisted thoracoscopic surgery (RATS) is now widely performed worldwide, and the use of robotic staplers is increasingly common. In this report, we present two cases in which pulmonary artery transection was interrupted due to activation of the robotic stapler's safety mechanism, labeled "Tissue Too Thick to Continue." Although no superfluous tissue was apparent upon inspection, the transaction was halted mid-procedure in both cases.
View Article and Find Full Text PDF