Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Robot-assisted thoracoscopic surgery (RATS) is now widely performed worldwide, and the use of robotic staplers is increasingly common. In this report, we present two cases in which pulmonary artery transection was interrupted due to activation of the robotic stapler's safety mechanism, labeled "Tissue Too Thick to Continue." Although no superfluous tissue was apparent upon inspection, the transaction was halted mid-procedure in both cases. Potential causes for this interruption include inappropriate cartridge selection for the tissue thickness, a dropped staple, or insufficient detachment of tissue in a visually inaccessible area. Malfunction or interruption of an automatic stapling device during vascular transection can lead to serious complications. Therefore, we believe this safety system should assess tissue suitability before initiating transection. Here, we describe how we managed these intraoperative events and discuss possible factors contributing to robotic stapler malfunction.

Download full-text PDF

Source
http://dx.doi.org/10.1111/ases.70144DOI Listing

Publication Analysis

Top Keywords

pulmonary artery
8
safety mechanism
8
"tissue thick
8
thick continue"
8
cases interrupted
4
interrupted pulmonary
4
artery dissection
4
dissection sureform
4
sureform smartfire
4
smartfire stapling
4

Similar Publications

Purpose: To evaluate the efficacy and complications of absorbable haemostatic gelatin uterine artery embolisation for symptomatic acquired uterine arterio-venous malformation (UAVM).

Methods: All the adult female patients who had acute urogenital bleeding due to UAVM confirmed on ultrasound and received uterine artery embolisation (UAE) for UAVM in a tertiary institution between January 2000 and October 2024 were included. Patients who had UAE for other causes were excluded.

View Article and Find Full Text PDF

Background: Paediatric patients who underwent surgery for mitral regurgitation (MR) have a high risk of recurrence or death; however, no prediction tool has been developed to risk-stratify this challenging subpopulation.

Methods: In this multicentre cohort study, paediatric patients undergoing surgery for congenital MR in Shanghai Children's Medical Center in January 1st, 2009-December 31st, 2022 were included for analysis while those had a combination with infective endocarditis, anomalous left coronary artery from the pulmonary artery, rheumatic valvular disease, connective tissue disease, or single ventricle were excluded. A Cox regression model predictive of the primary outcome (a composite of mortality or mitral valve [MV] re-operation) was derived and converted to a point-based risk score.

View Article and Find Full Text PDF

Uncovering a novel role of nAChRs in oxidative stress-mediated vascular dysfunction in COPD.

Redox Biol

August 2025

Department of Medicine, School of Medicine, Universidad Autónoma de Madrid, Madrid, Spain; Instituto Investigación Sanitaria-Princesa IIS-IP, Madrid, Spain; Centro de Investigación Biomédica en Red de Enfermedades Respiratorias (CIBERES), Instituto de Salud Carlos III, Madrid, Spain. Electronic

Tobacco smoke is the main risk factor for the development of chronic obstructive pulmonary disease (COPD). Despite current therapies alleviate symptoms there are limitations in the efficacy of treatments to curb its cardiovascular morbidities, particularly vascular dysfunction and the development of pulmonary hypertension. Our previous studies demonstrate that cigarette smoke directly contributes to pulmonary arterial dysfunction.

View Article and Find Full Text PDF

Fetal 4D Flow CMR for Advanced Diagnostics of Congenital Heart Disease: A Prospective Cohort Study.

Eur Heart J Cardiovasc Imaging

September 2025

Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany.

Aims: Fetal circulation undergoes complex changes in congenital heart disease (CHD) that are challenging to assess with fetal echocardiography. This study aimed to assess clinical feasibility and diagnostic value of 4D flow cardiac magnetic resonance (CMR) in fetal CHD.

Methods And Results: Pregnant women in advanced third trimester pregnancy with fetal CHD were prospectively recruited for fetal CMR between 08/2021 and 11/2024.

View Article and Find Full Text PDF