98%
921
2 minutes
20
Introduction: The International Society of Thrombosis and Hemostasis (ISTH) guidelines suggest a three-step evaluation for the detection of lupus anticoagulant (LA), including screening, mixing, and confirmation. According to the guidelines, the LA assay based on activated partial thromboplastin time (APTT) should include an initial screening step followed by a confirmatory step that uses a higher concentration of phospholipids in either bilayer or hexagonal form. For the activator, the guidelines recommend using silica, though ellagic acid is also an option. In this context, HemosIL Silica Clotting Time (SCT, Instrumentation Laboratory) is the only assay that fully complies with the guidelines. However, there are other assays available using different reagents, such as Dade Actin FSL/FS (Siemens Healthcare Diagnostics) and PTT-LA/Staclot LA (Diagnostica Stago), and the relevance of these differences in LA detection is not known.
Methods: This study compared the performance of the three platforms.
Results: Out of 136 samples, the majority were from females (82%) with a median age of 41 years (IQR 32-50); 44 (32%) had a history of thrombosis, and 28 (21%) were on anticoagulants. PTT-LA/Staclot LA had the highest sensitivity (100%) and specificity (100%). There was an almost perfect agreement between PTT-LA/Staclot LA and Dade Actin FSL/FS (kappa 0.812). HemosIL SCT sensitivity was 100% and the specificity was 74%, which was increased to 99% by increasing the phospholipid concentration of the screening step.
Conclusion: We observed a good agreement between PTT-LA/Staclot LA and Dade Actin FSL/FS, and fair to moderate agreement with HemosIL SCT, whose performance improved with increasing phospholipid concentration. These results demonstrate that all three assays are comparable for APTT-LA detection.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/ijlh.14549 | DOI Listing |
Introduction: The International Society of Thrombosis and Hemostasis (ISTH) guidelines suggest a three-step evaluation for the detection of lupus anticoagulant (LA), including screening, mixing, and confirmation. According to the guidelines, the LA assay based on activated partial thromboplastin time (APTT) should include an initial screening step followed by a confirmatory step that uses a higher concentration of phospholipids in either bilayer or hexagonal form. For the activator, the guidelines recommend using silica, though ellagic acid is also an option.
View Article and Find Full Text PDFHaemophilia
July 2025
State Key Laboratory of Experimental Hematology, National Clinical Research Centre for Blood Diseases, Haihe Laboratory of Cell Ecosystem, Institute of Hematology & Blood Diseases Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin, China.
Introduction: The Bethesda assay (BA) and the Nijmegen-Bethesda assay (NBA) are commonly used to measure inhibitors in patients with haemophilia A (HA). The laboratory results of inhibitor assays have been demonstrated to be highly variable.
Aims: To understand the current testing methods used in different laboratories in China and promote improvements in laboratory detection.
Heliyon
October 2024
Department of Pharmacy, Shenzhen Bao'an Traditional Chinese Medicine Hospital, Shenzhen, 518101, China.
Background: Bone-destructive diseases including rheumatoid arthritis (RA), osteoporosis, and bone metastases, are increasingly prevalent and worrisome due to the over-activated of osteoclasts. Chongrenside D (CGD) is a furostanol saponin extracted from Smilax china L, which has been demonstrated to have anti-inflammatory properties in our previous research. However, its effect on rheumatoid arthritis, especially on osteoclast differentiation and bone destruction has not yet been investigated.
View Article and Find Full Text PDFBlood Coagul Fibrinolysis
April 2024
Department of Laboratory Diagnostics, University Hospital Centre Zagreb.
Although clear and detailed recommendation regarding the lupus anticoagulant mixing test exist, various sources of NPP are used. We decided to inspect the possible differences in mixing studies depending on the mixing media. Four types of mixing media were prepared for 45 random remnant plasma samples: standard human plasma, control plasma N, previously analyzed patient with normal coagulation values, and home-made normal pool plasma (NPP).
View Article and Find Full Text PDFJ Clin Lab Anal
April 2022
Department of Laboratory Medicine, Medical University of Vienna, Vienna, Austria.
Introduction: We conducted a multicenter evaluation of a new one-stage factor VIII (FVIII) assay (Roche Diagnostics), intended for the quantitative assessment of FVIII activity. We evaluated the analytical performance of the FVIII assay on the cobas t 711 analyzer.
Methods: Experiments performed at three laboratories used 3.