Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Locking plates are widely used in open reduction internal fixation (ORIF) for proximal humeral fracture (PHF). However, the optimal surgical treatment of unstable, displaced PHF in elderly patients remains controversial. This study aimed to compare the radiological and clinical outcomes of surgical treatment of PHF in the elderly with locking plate (LP) alone and locking plate combined with 3D printed polymethylmethacrylate (PMMA) prosthesis augmentation (LP-PA).

Methods: From May 2015 to April 2021, a total of 97 patients aged ≥ 60 years with acute unstable PHF who underwent osteosynthesis with either LP (46 patients) or LP-PA (51 patients) were retrospectively analyzed. For the LP-PA group, a customized proximal humeral prosthesis made of PMMA cement was intra-operatively fabricated by a three-dimensional (3D) printed prototype mold for the humeral medial support. Radiological outcomes were analyzed by measuring the value of neck-shaft angle (NSA) and humeral head height (HHH). The clinical outcomes were evaluated using Constant-Murley Score (CMS), Disabilities of the Arm Shoulder and Hand (DASH) score, American Shoulder and Elbow Surgeons (ASES) score, and the shoulder range of motion (ROM). Pain was measured using a visual analogue scale (VAS).

Results: At the one-year follow-up, all fractures healed radiologically and clinically. The mean changes of NSA and HHH over the follow-up period were markedly smaller in the LP-PA group (3.8 ± 0.9° and 1.7 ± 0.3 mm) than those in the LP group (9.7 ± 2.1° and 3.2 ± 0.6 mm, both P < 0.0001). The LP-PA group also presented lower DASH score (17.1 ± 3.6), higher ASES score (89.5 ± 11.2) and better ROM in forward elevation (142 ± 26°) and external rotation (59 ± 11°) compared to the LP group (28.9 ± 4.8 for DASH score, P < 0.0001; 82.3 ± 9.0 for ASES score, P < 0.001; 129 ± 21° for forward elevation, P = 0.008; and 52 ± 9° for external rotation, P = 0.001). There was no significant difference in overall complication rate between the two groups, although the complication rate of screw perforation was higher in the LP-PA group (P = 0.172).

Conclusions: For PHF in elderly patients, the combination of LP fixation and PMMA prosthesis augmentation effectively improved humeral head support and reduction maintenance, providing satisfactory outcomes both radiologically and clinically. This technique also reduced the incidence of screw perforation associated with plate fixation alone, making it a reasonable option to ensure satisfactory clinical outcomes.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jse.2025.08.001DOI Listing

Publication Analysis

Top Keywords

locking plate
16
lp-pa group
16
phf elderly
12
clinical outcomes
12
dash score
12
ases score
12
plate locking
8
plate combined
8
combined printed
8
printed polymethylmethacrylate
8

Similar Publications

Objective: To explore the clinical efficacy of internal fixation of locking compression plate and Cannulated Screw in treatment of elderly femoral neck fractures.

Methods: 175 patients with femoral neck fractures admitted to our hospital from January 2022 to December 2022 were enrolled in the study. 93 cases in the control group were treated with Cannulated Screw internal fixation, and 82 cases in the observation group were treated with locking plate internal fixation.

View Article and Find Full Text PDF

Biomechanical comparison of locking plate and pin-tension band wiring fixation for 3D-printed canine patellar fracture repair.

Front Vet Sci

August 2025

Department of Veterinary Surgery, Graduate School of Veterinary Medicine, Konkuk University, Seoul, Republic of Korea.

Introduction: The conventional pin and tension band wiring (TBW) technique remains the standard for fixation, but is frequently associated with complications such as wire breakage, loosening, and delayed healing in patellar fracture. Locking plate fixation has demonstrated superior biomechanical stability in human studies. This study aimed to compare the biomechanical performance of locking plate fixation versus TBW in canine transverse patellar fractures and to evaluate the influence of plate design on fixation strength.

View Article and Find Full Text PDF

Study of a near-cortical over-drilling technique on plate constructs with a conical locking system in a rabbit femoral fracture using a finite element model.

Med Eng Phys

October 2025

Centre for Simulation in Bioengineering, Biomechanics and Biomaterials (CS3B), Department of Mechanical Engineering, School of Engineering of Bauru, São Paulo State University (UNESP), Bauru, São Paulo, Brazil. Electronic address:

This study aimed to evaluate the near-cortical over-drilling technique on the mechanical behaviour of bone-plate constructs in a rabbit transverse femoral fracture. In vitro biomechanical testing and finite element (FE) models were used for analyses. Rabbits' bones (n = 14) were divided into two groups: G1 - without near-cortical over-drilling, and G2 - with near-cortical over-drilling.

View Article and Find Full Text PDF

[Biphasic plate-Controlled instability in fracture healing].

Unfallchirurgie (Heidelb)

September 2025

Klinik für Unfall‑, Hand- und Wiederherstellungschirurgie, Universitätsklinikum Münster, Albert-Schweitzer-Campus 1, Gebäude W1, 48149, Münster, Deutschland.

The bony consolidation of fractures depends on various factors. Under optimal conditions fracture healing takes place within a few weeks. An essential requirement for fracture healing is the restoration of adequate biomechanical stability with an interfragmentary movement which is as ideal as possible.

View Article and Find Full Text PDF

Objective: To describe and compare arthroscopy-assisted (AA) with fluoroscopy-assisted (FA) minimally invasive plate osteosynthesis (MIPO) for simple transverse acetabular fractures.

Study Design: Ex vivo cadaveric study.

Sample Population: A total of 10 canine cadavers (>20 kg) without coxofemoral joint disease.

View Article and Find Full Text PDF