Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Surface electromyography (sEMG) signals are commonly utilized as a control source for upper-limb rehabilitation robots. Fast and high accuracy recognition of sEMG-based movements is crucial for the real-time control of robots. Here, we report a composite transformer-long short-term memory (LSTM) model for recognizing wrist-hand movements from sEMG signals. The sEMG data were collected to construct the training dataset. The consistent dataset was generated by a sliding window method to evaluate the model performance. We investigated the impact of window size and window increment on the sEMG-based recognition of wrist-hand movements. The results indicated that the recognition accuracy of the minimum window of 150 ms and the maximum window of 300 ms reached 94.68% and 99.35%, respectively. The recognition speeds were less than 0.3 ms. Finally, the trained transformer-LSTM model was combined with a majority voting strategy to determine the control outputs. The results confirm the model's capability for real-time and high-accuracy control with minimal delay. This method holds substantial significance for rapid feedback control of rehabilitation robots.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0271372DOI Listing

Publication Analysis

Top Keywords

wrist-hand movements
12
semg-based recognition
8
recognition wrist-hand
8
transformer-lstm model
8
semg signals
8
rehabilitation robots
8
control
5
window
5
movements
4
movements composite
4

Similar Publications

Surface electromyography (sEMG) signals are commonly utilized as a control source for upper-limb rehabilitation robots. Fast and high accuracy recognition of sEMG-based movements is crucial for the real-time control of robots. Here, we report a composite transformer-long short-term memory (LSTM) model for recognizing wrist-hand movements from sEMG signals.

View Article and Find Full Text PDF

The human hand is an exceptionally complex anatomical structure with 31 degrees of freedom. In the development of dynamic wrist-hand orthoses, the wrist's multiaxial mobility is of particular interest. To accurately replicate these natural movements, a promising approach is the use of compliant tensegrity structures.

View Article and Find Full Text PDF

PullExo: An orthosis-based mobile hand exoskeleton with on-device visual biofeedback.

J Hand Ther

August 2025

Department of Translational Medicine, Institute of Health Sciences, Bursa Uludag University, Bursa, Turkey; Department of Medical Genetics, Faculty of Medicine, Bursa Uludag University, Bursa, Turkey. Electronic address:

Background: Grasping function is severely compromised in individuals with spinal cord injury, significantly limiting their independence in activities of daily living. While robotic hand exoskeletons offer promising solutions, current systems often separate control and motor units from the wearable body, resulting in additional components to be worn by the patient. Furthermore, the integration of an immediately accessible user interface, capable of providing biofeedback, has not been fully explored.

View Article and Find Full Text PDF

Introduction: Injury to triangular fibrocartilage complex (TFCC) is a common cause of ulnar-sided wrist pain, of which peripheral TFCC tears are amenable to repair. The surgical approaches to treat TFCC tears are well-established, with arthroscopic or arthroscopic-assisted repair as the preferred method. However, the postoperative rehabilitation protocols significantly vary across different studies, ranging from 2 to 9 weeks, often without sufficient justification.

View Article and Find Full Text PDF

High-density electromyography (EMG) decomposition technology enables the myoelectric control on the level of individual motor units (MUs). Compared to traditional EMG-based control schemes, the MU-based control strategy exhibits enhanced reliability and superiority in the decoding of continuous motion and real-time control. Current MU-based control schemes are usually limited to one or two degrees of freedom (DoFs), reducing intuitiveness.

View Article and Find Full Text PDF