Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Intra-abdominal pressure (IAP) may increase in acute decompensated heart failure (ADHF) due to fluid accumulation in the splanchnic system, contributing to renal venous congestion and impaired diuresis. This study aimed to evaluate the predictive value of IAP for early diuretic response in patients with ADHF.

Methods: This prospective, single-center study included 83 patients (mean age 71.6 ± 13.6 years, 58.9% female) admitted to the intensive care unit for ADHF. Patients requiring renal replacement therapy or in refractory shock were excluded. Guideline-directed medical therapy including intravenous loop diuretics was administered. The IAP was measured intravesically via Foley catheter and pressure transducer before treatment initiation. Elevated IAP was defined as >8 mm Hg. Abdominal perfusion pressure (APP) was calculated as mean arterial pressure minus IAP.

Results: Patients were divided into elevated IAP (n = 44) and normal IAP (n = 39) groups. Baseline demographics were comparable. The APP was significantly lower in the elevated IAP group (65.3 vs. 74 mm Hg; P = .008). The IAP showed a moderate negative correlation with 24-hour and 48-hour urine output (R2 = 0.192 and 0.131). Each 1 mm Hg increase in IAP was associated with a 213 mL and 310 mL decrease in urine output at 24 and 48 hours, respectively.

Conclusion: Intravesical IAP measurement may serve as a practical tool to predict short-term diuretic response in ADHF. Elevated IAP and reduced APP could help identify patients requiring intensified decongestive strategies.

Download full-text PDF

Source
http://dx.doi.org/10.14744/AnatolJCardiol.2025.5494DOI Listing

Publication Analysis

Top Keywords

elevated iap
16
iap
11
heart failure
8
diuretic response
8
patients requiring
8
urine output
8
patients
6
intravesical pressure
4
pressure monitoring
4
monitoring practical
4

Similar Publications

Ozone dry deposition and chemical removal in the urban environment of Beijing: I. Chemical and meteorological controlling parameters.

Sci Total Environ

September 2025

The Robert H. Smith Faculty of Agriculture, Food and Environment, Department of Soil and Water Sciences, The Hebrew University of Jerusalem, Rehovot, Israel. Electronic address:

Tropospheric ozone (O) is a major air pollutant that negatively affects human health and vegetation, and plays a central role in climate change and atmospheric chemistry. Current simulations of tropospheric O concentrations in climate and air-quality models are significantly limited by the inaccurate representation of O dry deposition rate-particularly in urban areas, where field measurements remain scarce. We hypothesize that O dry deposition in the urban environment is controlled by factors similar to those over vegetation, albeit via potentially different mechanisms.

View Article and Find Full Text PDF

Impact of Large Ventral Hernia Repair on Postoperative Renal Function.

J Am Coll Surg

August 2025

Cleveland Clinic Center for Abdominal Core Health, Department of General Surgery, Cleveland Clinic Foundation, Cleveland, OH.

Introduction: Large hernia repairs, particularly those involving abdominal wall reconstruction (AWR), can elevate intra-abdominal pressure (IAP) due to the reintegration of herniated contents into the abdominal cavity, potentially contributing to renal injury. Despite the theoretical risk, the long-term impact of AWR-induced IAP elevation on renal function remains insufficiently studied. This study aims to evaluate the incidence of acute kidney injury (AKI) and chronic kidney disease (CKD) following AWR and to identify key factors associated with postoperative renal impairment.

View Article and Find Full Text PDF

Background: Recent studies confirm that intra-abdominal hypertension (IAH) frequently develops in critically ill patients, posing a significant risk of organ failure and increased mortality. Accurate intra-abdominal pressure (IAP) measurement is essential for effective diagnosis, prevention, and treatment. Previous studies indicate that accurate IAP measurement using traditional Foley catheters requires the bladder to be filled with a maximum of 25 mL of sterile saline solution after clamping the catheter, restricting the ability to monitor IAP continuously due to variations in the bladder fill volume.

View Article and Find Full Text PDF

Background: Dynamic monitoring of intra-abdominal pressure is a reliable basis for diagnosing intra-abdominal hypertension and abdominal compartment syndrome, which are independent risk factors for death. The latest evidence on abdominal pressure monitoring has been updated, but the gap between these updates and the actual practice of critical care nurses remains unknown. This study aimed to assess the behaviour and cognition of adult critical care nurses in China regarding intra-abdominal pressure measurement.

View Article and Find Full Text PDF

Background: Intra-abdominal pressure (IAP) may increase in acute decompensated heart failure (ADHF) due to fluid accumulation in the splanchnic system, contributing to renal venous congestion and impaired diuresis. This study aimed to evaluate the predictive value of IAP for early diuretic response in patients with ADHF.

Methods: This prospective, single-center study included 83 patients (mean age 71.

View Article and Find Full Text PDF