A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

A Bottom-Up Approach Integrating Computer Vision with Material Flow Analysis to Estimate the Recycling Potential of Distributed Solar Panels Using Satellite Imagery. | LitMetric

A Bottom-Up Approach Integrating Computer Vision with Material Flow Analysis to Estimate the Recycling Potential of Distributed Solar Panels Using Satellite Imagery.

Environ Sci Technol

Sustainable Bioeconomy Research Group, Department of Wood Science, The University of British Columbia, Vancouver, British Columbia V6T 1Z4, Canada.

Published: September 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The rapid deployment of solar photovoltaic (PV) systems has created a growing challenge in managing end-of-life panels. While many studies project future recycling potential, they are often limited by the lack of data on existing distributed PV installations. To address this need, we developed SolarScope, an open-source model that integrates computer vision (CV) with dynamic material flow analysis (dMFA) to automatically identify distributed PV panel areas and evaluate the urban mining potential. By leveraging satellite imagery and Vision Transformer (ViT) models, SolarScope achieves an Area under the Receiver Operating Characteristic Curve (AUROC) of 0.93 for classification and a Dice Similarity Coefficient (Dice) score of 0.90 for segmenting distributed PV installations. A case study in Kamakura, Japan, demonstrates the model's transferability and its ability to support material recovery assessments at fine spatial scales. We present a methodological framework that combines CV with dMFA to bottom-up estimate the regional material stock and recycling potential of distributed PV systems, providing a scalable solution to overcome data limitations in conventional material flow analysis and contributing to circular economy advancement.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.est.5c01600DOI Listing

Publication Analysis

Top Keywords

material flow
12
flow analysis
12
recycling potential
12
computer vision
8
potential distributed
8
satellite imagery
8
distributed installations
8
material
5
distributed
5
bottom-up approach
4

Similar Publications