Article Abstract

Objective: Due to volume fluctuations, bony prominences contacting prosthetic sockets are susceptible to skin breakdown due to constant pressure and shear stresses from lateral and vertical displacements throughout gait. A low-profile unloading cushion that can be controlled with a millisecond response to dynamically provide localized socket fit at the fibular head may offer stress relief during gait.

Methods: The study presents a low-profile (<0.5 mm thick) dynamic fluidic cushion that can provide targeted cushioning during gait to mitigate high contact pressures at bony prominences while minimizing duration of pressure and shear. The proof-of-concept study comprised benchtop testing using a residual limb model.

Results: The dynamic cushion effectively unloaded high pressure caused by the body weights only during the stance phase at the fibular head for up to 80 kg by mitigating and redistributing contact pressures away from the fibular head to the immediately surrounding soft tissues. Results demonstrated that the fibular head peak contact pressure could be reduced by as much as 94% (98 to 6 kPa) with a response time of 250 milliseconds in benchtop tests, fast enough to turn on during stance and off during swing.

Conclusion: The proposed dynamic fluidic cushion has the potential to offer unloading during gait to prevent skin damage at pressure-sensitive spots, notably benefiting individuals with complex limb geometries.

Significance: We introduce a new method with the potential to be integrated into prosthetist workflows to locally adjust socket fit (e.g., at the fibular head) using elastomer sheets and a handheld heat press.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TBME.2025.3600562DOI Listing

Publication Analysis

Top Keywords

soft dynamic
4
dynamic fluidic
4
fluidic cushion
4
cushion pressure
4
pressure sore
4
sore management
4
management transtibial
4
transtibial prosthetics
4
prosthetics proof-of-concept
4
proof-of-concept study
4

Similar Publications

Soft wearable sensors offer promising potential for advanced diagnostics, therapeutics, and human-machine interfaces. Unlike conventional devices that are bulky and rigid, often compromising skin integrity, comfort, and user compliance, soft wearable sensors are flexible, conformable, and better suited to the dynamic skin surface. This improved mechanical integration enhances signal fidelity and device performance, while also enabling safer, more comfortable, and continuous physiological monitoring in real-world environments.

View Article and Find Full Text PDF

Globular proteins as functional-mechanical materials: a multiscale perspective on design, processing, and applications.

Mater Horiz

September 2025

MOE Key Laboratory of Macromolecule Synthesis and Functionalization, Department of Polymer Science and Engineering, Zhejiang University, Hangzhou, 310027, PR China.

Globular proteins, traditionally regarded as non-structural biomolecules due to the limited load-bearing capacity in their monomeric states, are increasingly recognized as valuable building blocks for functional-mechanical materials. Their inherent bioactivity, chemical versatility, and structural tunability enable the design of materials that combine biological functionality with tailored mechanical performance. This review highlights recent advances in engineering globular proteins-spanning natural systems (serum albumins, enzymes, milk globulins, silk sericin, and soy protein isolates) to recombinant architectures including tandem-repeat proteins-into functional-mechanical platforms.

View Article and Find Full Text PDF

Impact of Flow Restrictors on Aerosol Delivery of the Respimat® Soft Mist Inhaler.

Pulm Ther

September 2025

Boehringer Ingelheim Pharma GmbH & Co. KG, Binger Straße 173, 55216, Ingelheim am Rhein, Germany.

Introduction: The modification of an inhaler's air flow resistance influences a patient's inhalation flow profile, thereby affecting the exit velocity of an aerosol leaving the Respimat® mouthpiece. A slower inhalation maneuver results in reduced plume velocity and thus a decreased oropharyngeal deposition due to reduced impaction. This could not only lead to fewer unwanted side effects associated with inhaled therapies, but also enhance lung deposition.

View Article and Find Full Text PDF

Transfer RNA (tRNA) plays an essential role in protein translation, and tRNA modifications are important to their function. Recently, nanopore direct RNA sequencing (dRNA-seq) has shown promising results in the detection of complex tRNA modifications. However, its wider adoption in the tRNA field has been limited by a lack of (de)multiplexing solutions.

View Article and Find Full Text PDF

Inescapable Anisotropy of Nonreciprocal XY Models.

Phys Rev Lett

August 2025

Laboratoire de Physique Théorique de la Matière Condensée, Sorbonne Université, CNRS, 75005 Paris, France.

We investigate nonreciprocal XY (NRXY) models defined on two-dimensional lattices in which the coupling strength of a spin with its neighbors varies with their position in the frame defined by the current spin orientation. As expected from the seminal work of Dadhichi et al., [Nonmutual torques and the unimportance of motility for long-range order in two-dimensional flocks, Phys.

View Article and Find Full Text PDF