A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Digital measurement of pupil size, corneal size, and eccentricity in Guinea pigs using python compared with traditional OCT. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Unlabelled: To develop a Python-based digital technique for accurate measurement of pupil size, corneal size, and eccentricity in guinea pigs, and to validate its efficiency and accuracy against traditional OCT methods in ophthalmology research.

Methods: Fourteen healthy guinea pigs were selected, and the eye images were captured using a camera, and the image analysis program was written by Python 3.9. The program integrated edge detection (Canny algorithm), curve fitting (conic curve equation) and pixel-actual distance conversion modules, and designed a graphical user interface (GUI) to visualize the operation. Measured parameters included pupil size, corneal size and eccentricity to compare the difference between in vivo and ex vivo measurements and to verify the accuracy of the method.

Results: The Python program clearly identified the guinea pig pupil and corneal limbus, and the fitted curves were in high agreement with the actual contours. Pupil and corneal size measured with an accuracy of 0.01 mm. In vivo and in vitro measurements showed that pupil size increased significantly after ex vivo (p < 0.001), whereas there was no significant difference in eccentricity (p = 0.38). Compared to optical coherence tomography (OCT), the method did not differ significantly in accuracy (p > 0.05), but significantly improved efficiency and reduced reliance on specialized equipment.

Conclusion: The Python-based digital measurement technique can effectively and accurately quantify the morphological parameters of the guinea pig eye, providing reliable technical support for non-contact measurements in experimental animals.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12358525PMC
http://dx.doi.org/10.1038/s41598-025-13096-yDOI Listing

Publication Analysis

Top Keywords

pupil size
16
corneal size
16
size corneal
12
size eccentricity
12
guinea pigs
12
digital measurement
8
measurement pupil
8
size
8
eccentricity guinea
8
traditional oct
8

Similar Publications