Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Biophysical models of diffusion tailored to quantify gray matter microstructure are gathering increasing interest. The two-compartment Neurite EXchange Imaging (NEXI) model has been proposed recently to account for neurites, extra-cellular space, and exchange across the cell membrane. NEXI parameter estimation requires multi-shell multi-diffusion time data and has so far only been implemented experimentally on animal data collected on a preclinical magnetic resonance imaging (MRI) set-up. In this work, the translation of NEXI to the human cortex in vivo was achieved using a 3 T Connectom MRI system with 300 mT/m gradients, that enables the acquisition of a broad range of b-values (0 - 7.5 ms/µm²) with a window covering short to intermediate diffusion times (20 - 49 ms) suitable for the characteristic exchange times (10 - 50 ms). Microstructure estimates of four model variants: NEXI, NEXI(its extension with the addition of a dot compartment), and their respective versions that correct for the Rician noise floor (NEXIand NEXI) that particularly impacts high b-value signal, were compared. The reliability of estimates in each model variant was evaluated in synthetic and human in vivo data. In the latter, the intra-subject (scan-rescan) versus between-subjects variability of microstructure estimates was compared in the cortex. The better performance of NEXIhighlights the importance of correcting for Rician bias in the NEXI model to obtain accurate estimates of microstructure parameters in the human cortex, and the sensitivity of the NEXI framework to individual differences in cortical microstructure. This application of NEXI in humans represents a significant step, unlocking new avenues for studying neurodevelopment, aging, and various neurodegenerative disorders.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12247613 | PMC |
http://dx.doi.org/10.1162/imag_a_00104 | DOI Listing |