Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Low and dense cloud cover is often encountered in daily observing experiments with lidar. In such scenarios, the laser cannot penetrate the clouds and it is not possible to use the clean atmosphere to initially calibrate the calibration heights required for the actual inversion, which can pose a significant challenge to the inversion of aerosols under clouds. This paper proposes an iterative proximal calibration algorithm based on slope method and Fernald's backward integral equation, combined with the inherent observational mode characteristics of the micro infrared lidar (mIRLidar). By conditioning the iterative process, the relative error between the obtained extinction coefficient value and the true value becomes smaller and smaller as the number of iterations increases. According to the inversion results of the actual lidar observation data, it can be tentatively concluded that the use of the proximal calibration iterative algorithm eliminates the limitations of the traditional Fernald height calibration method and improves the accuracy of the under-cloud aerosol inversion.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.541208DOI Listing

Publication Analysis

Top Keywords

proximal calibration
8
iterative
4
iterative inversion
4
inversion method
4
method retrieving
4
retrieving optical
4
optical properties
4
properties aerosol
4
aerosol cloud
4
cloud ground-based
4

Similar Publications

The adaptive calibration model (ACM) asserts that the stress response system, including the parasympathetic nervous system (PNS), conditionally adapts to one's environment. In infancy, the proximal context of parental influences (e.g.

View Article and Find Full Text PDF

Unlabelled: Accurate assessment of proximal humeral volumetric bone mineral density (vBMD) is essential for surgical planning in shoulder pathology. However, age-related changes in proximal humeral vBMD remain poorly characterized. This study developed a deep learning-based method to assess proximal humeral vBMD and identified sex-specific age-related changes.

View Article and Find Full Text PDF

Background: Proximal femoral malunions with implants in-situ pose a significant challenge for pre-operative planning due to the obstruction of key anatomical landmarks. Existing planning software, while advanced, is often limited by cost, accessibility and a lack of functionality for digital implant removal. The main objective is to introduce a novel, low-cost and accessible two-step digital method for planning deformity correction using Picsart and Microsoft PowerPoint.

View Article and Find Full Text PDF

Low and dense cloud cover is often encountered in daily observing experiments with lidar. In such scenarios, the laser cannot penetrate the clouds and it is not possible to use the clean atmosphere to initially calibrate the calibration heights required for the actual inversion, which can pose a significant challenge to the inversion of aerosols under clouds. This paper proposes an iterative proximal calibration algorithm based on slope method and Fernald's backward integral equation, combined with the inherent observational mode characteristics of the micro infrared lidar (mIRLidar).

View Article and Find Full Text PDF

Objective: To investigate the risk factors associated with the development of knee osteoarthritis (OA) following arthroscopic surgery for degenerative lesions of the posterior horn of the medial meniscus.

Methods: Between January 2012 and January 2014, a retrospective analysis was conducted on 506 patients who underwent arthroscopic surgery for degenerative disease of the posterior horn of the medial meniscus. The cohort included 230 males and 276 females, aged from 32 to 58 years old with an average of (46.

View Article and Find Full Text PDF