Highlights: Compressed air strategy was evaluated as a grain entrapment prevention method. Nozzle types affected compressed air efficiency. Open ½ inch nozzles performed best. Mid-scale experiment confirmed compressed air utility in breaking grain clumps. Dust, fungal, and noise levels exceeded maximum limits during operations, and PPE must be worn properly before using compressed air to break grain clumps.
Abstract: Grain entrapment, a severe and often fatal agricultural hazard, continues to pose a significant challenge in grain storage and handling. These incidents are often due to out-of-condition grain blocking outlets, leading to workers frequently entering the grain bin to dislodge grain. This study evaluates the utility of compressed air as a preventive measure to break up grain clumps located at bin outlets by conducting pilot and full-scale experiments using an air compressor. This study also evaluated potential hazards due to the use of air compressors. Three nozzle types were tested: open ½ inch, Crimped ½ inch, and the AirSpade. The findings indicated that the open ½ inch nozzle was the most efficient, with an average clearing time of 15 minutes per run, outperforming the crimped and AirSpade nozzles. Noise levels during operation ranged up to 105 dBA, with dust and fungal spore concentrations exceeding safety limits inside the grain bins and returning to acceptable levels shortly after operation. Full-scale testing indicates that compressed air can be useful in unclogging bins. The study underscores the potential of compressed air to enhance grain handling safety, offering practical safety recommendations and suggesting the need for further research to optimize and standardize its use in preventing grain entrapment.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.13031/jash.16210 | DOI Listing |
Proc Natl Acad Sci U S A
September 2025
Department of Surgery, The University of Chicago, Chicago, IL, 60637.
Self-assembled thin films respond to external loads via surface instabilities that are critical to their functionality in both biology and technology. Lipid monolayers at the air-liquid interface are one such system. Tunability between out-of-plane buckling (e.
View Article and Find Full Text PDFJ Radiol Prot
September 2025
Radiological Physics & Advisory Division, Bhabha Atomic Research Centre, Mumbai, Maharashtra, INDIA.
Purpose This foundational study aims to support the development of regional Diagnostic Reference Levels (DRLs) for mammography screening in India by estimating Mean Glandular Dose (MGD) using appropriate breast-equivalent phantoms across Computed Mammography (CR), Digital Mammography (DR), and Digital Breast Tomosynthesis (DBT) systems. Additionally, system-displayed MGD values were compared with calculated MGDs to evaluate their accuracy for routine clinical use. Methods A total of 5,000 mammographic views were collected across CR, DR, and DBT units.
View Article and Find Full Text PDFInt J Mol Sci
August 2025
Atmosphere Optics, Spectroscopy and Laser Laboratory (LOASL), Faculty of Physics, Alexandru Ioan Cuza University of Iasi, 11 Carol I Bld., 700506 Iasi, Romania.
Numerous studies on specific cannabis compounds (cannabinoids and phenolic acids) have demonstrated their therapeutic potential, with their administration methods remaining a key research focus. Transdermal drug delivery (TDD) systems are gaining attention due to their advantages, such as painless administration, controlled release, direct absorption into the bloodstream, and its ability to bypass hepatic metabolism. The thin films obtained via pulsed laser deposition consist of micro- and nanoparticles capable of migrating through skin pores upon contact.
View Article and Find Full Text PDFJ Aerosol Med Pulm Drug Deliv
August 2025
Jolyon Mitchell Inhaler Consulting Services Inc., London, Canada.
The "Miller" design of mixing inlet (MI) enables a cascade impactor to operate at a constant flow rate while the orally inhaled product-on-test is evaluated at varying flow rates by controlling the flow of air via its side-arm. As part of the European Pharmaceutical Aerosol Group (EPAG) Impactor subgroup, we report a cross-industry experimental investigation by five organizations to determine internal losses of different inhaler-generated aerosolized medications within commercially available MIs, focusing on pharmacopeial methods for product testing. Evaluations were undertaken of solution and suspension formulations delivered by pressurized metered dose inhalers (pMDIs), passive dry powder inhalers (DPIs), and compressed air-jet and vibrating mesh nebulizers.
View Article and Find Full Text PDFSci Rep
August 2025
Department of Engineering, Islamic Azad University of Shahreza Branch, Shahreza, Iran.