A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: Network is unreachable

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

A retrospective study of automatic progressive optimization for lung cancer radiotherapy plans on the Halcyon and RayStation systems. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

This study aims to evaluate the feasibility of using RayStation's scripting function to generate automated radiotherapy plans for non-small cell lung cancer (NSCLC) patients on a Varian Halcyon accelerator and to compare their dosimetric characteristics with those of retrospectively collected manual clinical plans. A total of 63 conventional fractionation plans for NSCLC, previously designed using RayStation 4.5 for a variety of linear accelerators-including Trilogy, TrueBeam, Halcyon, and Elekta Infinity-were compared with automated plans generated using RayStation 9.0 for Halcyon. This heterogeneous control group was chosen to reflect real-world clinical practice across multiple platforms. Target coverage, doses to organs at risk (OARs), monitor units, and plan complexity were assessed. The automated plans showed improved dose conformity and lower OAR exposure under the planning configuration used. However, these differences should be interpreted with caution, as the comparison involved different treatment planning systems (TPS) versions and hardware platforms. Further controlled studies using the same TPS and linac are needed to validate the observed improvements.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12333610PMC
http://dx.doi.org/10.7717/peerj.19831DOI Listing

Publication Analysis

Top Keywords

lung cancer
8
radiotherapy plans
8
automated plans
8
plans
6
retrospective study
4
study automatic
4
automatic progressive
4
progressive optimization
4
optimization lung
4
cancer radiotherapy
4

Similar Publications