98%
921
2 minutes
20
This study aimed to evaluate the electrical characteristics of the da Vinci system's bipolar soft coagulation mode and to assess its feasibility for dividing incomplete pulmonary interlobar fissures during robot-assisted thoracoscopic surgery. The electrical properties of the bipolar soft coagulation mode were analyzed using an electrocautery analyzer. Additionally, safety was assessed through experiments on animal tissue with an infrared thermographic camera. Finally, a retrospective review of clinical cases was conducted to evaluate the use of bipolar soft coagulation forceps for dividing incomplete interlobar fissures in robot-assisted thoracoscopic surgery. Resistance-voltage curves exhibited a plateau phase across all settings, ranging approximately from 53 to 120 V. No carbonization was observed in animal tissue at temperatures below 100 °C. In 23 robot-assisted lung resections using bipolar soft coagulation forceps, the average number of stapler cartridges required for interlobar division was significantly lower compared to the stapler group. Perioperative outcomes were comparable between the two groups. Bipolar soft coagulation forceps are a feasible and safe alternative for dividing incomplete pulmonary interlobar fissures in robot-assisted thoracoscopic surgery, with the added benefit of reducing stapler usage.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s11701-025-02635-4 | DOI Listing |
Endoscopy
December 2025
Third Department of Internal Medicine, Division of Gastroenterology and Hepatology, Kansai Medical University Hirakata Hospital, Hirakata, Japan.
Front Psychiatry
July 2025
Department of Affective Disorders, Jagiellonian University Medical College, Cracow, Poland.
Background: Patients with bipolar disorder (BD) present motor dysfunctions in the form of neurological and cerebellar soft signs (NSS and CSS, respectively). Little is known about the clinical utility of these symptoms and their impact on patients' psychosocial functioning. The aim of our study is to assess the relationships between severity of NSS and CSS, as well as various dimensions of the daily functioning of patients with BD.
View Article and Find Full Text PDFSci Rep
August 2025
Department of Mathematics, College of Science, University of Duhok, Duhok, 42001, Duhok, Iraq.
Sustainability evaluation in manufacturing industries is increasingly vital for promoting responsible growth and long-term competitiveness amid environmental, social, and economic challenges. Effective decision-making (DM) under uncertainty is crucial for managing multiple, often conflicting sustainability objectives. In this paper, we propose a novel hybrid model, termed Pythagorean fuzzy N-bipolar soft sets (PFNBSSs), which integrates Pythagorean fuzzy sets (PFSs), N-soft sets (NSSs), and bipolar soft sets (BSSs) within a unified multi-criteria decision-making (MCDM) framework.
View Article and Find Full Text PDFEur J Protistol
July 2025
Department of Biology, Gangneung-Wonju National University, Gangneung 25457, South Korea. Electronic address:
The morphology and multi-gene phylogeny of Rubrioxytricha hasllaensis n. sp., a non-oxytrichid dorsomarginalian ciliate discovered in a brackish water habitat in South Korea, were investigated.
View Article and Find Full Text PDFJ Robot Surg
August 2025
Department of Thoracic Surgery, Tenri Hospital, 200 Mishima, Tenri, Nara, 632-8552, Japan.
This study aimed to evaluate the electrical characteristics of the da Vinci system's bipolar soft coagulation mode and to assess its feasibility for dividing incomplete pulmonary interlobar fissures during robot-assisted thoracoscopic surgery. The electrical properties of the bipolar soft coagulation mode were analyzed using an electrocautery analyzer. Additionally, safety was assessed through experiments on animal tissue with an infrared thermographic camera.
View Article and Find Full Text PDF