A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

The Effect of Conventional and Microwave Frying on the Quality Characteristics of French Fries. | LitMetric

The Effect of Conventional and Microwave Frying on the Quality Characteristics of French Fries.

J Food Sci

Department of Food Science and Human Nutrition, University of Illinois, Urbana-Champaign, Urbana, Illinois, USA.

Published: August 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Fried foods have a widespread appeal worldwide, but consumers are cautious about their high-calorie density and oil content. We evaluated microwave frying (MF) at 2.45 and 5.8 GHz frequencies as potential alternatives to conventional frying (CF) to produce fried foods containing less oil. MF is expected to lead to higher magnitudes of pressure in the food matrix than CF, which can provide higher resistance to oil penetration into the food. Real-time temperature and pressure measured using fiber optic sensors showed that MF resulted in faster sample heating and generated higher internal pressure than CF. The peak sample temperature and internal gauge pressure were the highest for MF at 2.45 GHz (107.3°C, 24.9 kPa), followed by MF at 5.8 GHz (104.1°C, 20.8 kPa) and CF (100.5°C, 13.8 kPa). The results indicated that the microwaves were not completely attenuated while traveling through the bulk oil and could penetrate the French fries. Below a sample moisture content of 3 g/g solids, the oil content increased rapidly with reducing moisture content for CF; the increase in oil content was relatively slower for MF at 5.8 GHz and negligible for MF at 2.45 GHz. This indicated that MF is an effective substitute for CF to produce lower oil content French fries with similar endpoint moisture content. The stress relaxation data showed that MF at 5.8 GHz produced stiffer (crunchier) French fries, which could be due to the intense crust heating. PRACTICAL APPLICATIONS: The current study showed that microwave frying can reduce frying times and produce French fries with lower oil content than conventional frying. This can help the food industry reduce processing times and offer consumers healthier fried foods. The insights generated from this work can help design process optimization studies and guide the physics-based modeling of microwave frying.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12319142PMC
http://dx.doi.org/10.1111/1750-3841.70441DOI Listing

Publication Analysis

Top Keywords

french fries
20
oil content
20
microwave frying
16
fried foods
12
moisture content
12
oil
8
content
8
conventional frying
8
lower oil
8
frying
7

Similar Publications