Low impact development sand filter media replacement: Costs and effect on pollutant removal efficiencies.

J Environ Manage

School of Civil & Environmental Engineering, and Construction Management, The University of Texas at San Antonio, San Antonio, TX, 78249, USA.

Published: September 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Sand filter basins are widely utilized as a Best Management Practice (BMP) in Texas and other regions for stormwater mitigation. Efficient operation of these systems depends on routine inspections and maintenance. The performance of the sand filter's contaminant removal before and after media maintenance was evaluated along with cost variations for the maintenance activities. Maintenance concerns were also identified in inspection records from 2017 to 2022 for sand filter and sedimentation basins treating areas over the contributing zone of Edwards Aquifer (within Bexar County, TX). The results indicated minimal change in the removal ability for suspended solids after a replacement of the top media layer. A decline in removal for parameters including total coliforms, total nickel and total lead suggests disruption of biofilm layer on the media surface (schmutzdecke) during maintenance. Media replacement costs are rarely documented for sand filter BMPs but must be incurred to satisfy regulatory guidelines. The average total cost of media replacement by private firms or government entities in the local area was $18,462 ± 6325 which included removal and replacement of the top layer of sand and disposal of the removed sand off site.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jenvman.2025.126765DOI Listing

Publication Analysis

Top Keywords

sand filter
16
media replacement
12
replacement costs
8
replacement top
8
sand
7
media
6
replacement
5
removal
5
maintenance
5
low impact
4

Similar Publications

Static magnetic field enhances biogenic Mn (II) oxidation in magnetite sand filtration to strengthen the removal of emerging contaminants in groundwater.

Water Res

August 2025

State Key Laboratory of Regional Environment and Sustainability, School of Environment, Tsinghua University, Beijing 100084, China; Beijing Laboratory of Environment Frontier Technologies, School of Environment, Tsinghua University, Beijing 100084, China; Key Laboratory of Drinking Water Science and

Oligotrophic groundwater limits biodegradation in sand filtration, illuminating the pathway of the in-situ production of oxidatively active Mn oxide (MnOx) to remove emerging contaminants (ECs). Based on the Mn(II) removal filter, increased production of chemical MnOx (CheMnOx) for EC removal could be realized by increasing biogenic MnOx (BioMnOx) as the Mn active film to stimulate autocatalytic Mn(II) oxidation. However, progress in exogenously enhancing biogenic Mn(II) oxidation is limited.

View Article and Find Full Text PDF

In recent years, the use of supplementary cementitious materials (SCMs) in building materials has increased due to concerns about CO emissions from the cement industry. On the other hand, the scarcity of traditional sources of SCMs in certain regions exacerbates the issue of high demand for these materials in concrete production. In this context, this article explores the chemical, mineralogical, morphological, and physical properties and pozzolanic activity of two types of diatomaceous earth (DE) obtained from industrial waste and by-products.

View Article and Find Full Text PDF

Household slow sand filters are considered simple, efficient, and low-cost solutions for accessing drinking water in isolated communities. To ensure safe handling, it is essential for their operation to be simple and reliable, while requiring the lowest possible frequency of maintenance, as this will be carried out by the residents themselves. This is the first study to evaluate the performance of intermittent biosand filters (BSFs) using a polyurethane sponge positioned on top of the filter media, acting as a physical pre-treatment barrier.

View Article and Find Full Text PDF

Mitigation of combined fouling by gypsum and humic acid in membrane distillation via synergistic foulant capture mechanism.

Water Res

August 2025

Key Laboratory for Water Quality and Conservation of the Pearl River Delta, Guangzhou University, Guangzhou 510006, China. Electronic address:

Mineral scaling and scaling induced wetting remain the primary bottlenecks for membrane distillation (MD) during saline wastewater treatment. The in-line granular filtration using modified activated alumina (MAA) was effective in mitigating MD scaling, while the accurate design of filter media properties would benefit this technology in long-term operation. This study focused on the mechanism of mitigation of gypsum-organic combined fouling in MD by mixed filter media (MAA and granular activated carbon, sand, zeolite or fiber).

View Article and Find Full Text PDF

This study presents an analysis of the morphology of sand particles and their contacts using high-resolution microcomputer tomography (CT) and scanning electron microscopy (SEM). Raw 3D images are filtered, binarized, and smoothed to distinguish the granular space from the void space. The 3D granular space is segmented via an advanced adaptive watershed algorithm.

View Article and Find Full Text PDF