Pilot study evaluating lipoma reduction with injected physiologic ice slurry.

Front Vet Sci

Department of Biostatistics, School of Public Health, Boston University, Boston, MA, United States.

Published: July 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: This study aimed to assess the adverse event profile following injection of canine lipomas with BXT-786 coolant, and to assess its impact on lipoma size.

Methods: Ten healthy adult client-owned animals, each with two similarly sized, cytologically confirmed lipomas were enrolled. Lipomas were injected with either BXT-786 coolant or control room temperature 0.9% saline solution. Two blinded, independent observers measured lipomas with a caliper and ultrasound. Dogs were reevaluated at 2, 4, 8, and 12-weeks post-injections to assess for adverse events and repeat measurements. Lipomas were surgically removed at 12 weeks post injection and submitted for histopathologic analysis. Health related quality of life was assessed using an owner completed questionnaire. Response to treatment was determined and adverse events were reported and graded.

Results: Based on caliper assessment, majority of the lipomas were determined to be stable in size prior to surgical excision after BXT-786 or saline injection. Greater variability in response assessment was observed when using ultrasound. No statistically significant change was found in patient quality of life over an 8-week period. Adverse events were typically unrelated to BXT-786 injection, although one dog did develop cellulitis and mild necrosis in the lipoma.

Conclusion: Injection of BXT-786 coolant into lipomas was feasible and did induce some histopathologic changes consistent with effects on tumor cells, but it did not result in tumor shrinkage. Future studies could explore using coolants with more sustained coolant function and multiple injections to promote more efficient tumor reduction.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12312678PMC
http://dx.doi.org/10.3389/fvets.2025.1630506DOI Listing

Publication Analysis

Top Keywords

bxt-786 coolant
12
adverse events
12
assess adverse
8
quality life
8
lipomas
7
injection
5
bxt-786
5
pilot study
4
study evaluating
4
evaluating lipoma
4

Similar Publications

Objective: This study aimed to assess the adverse event profile following injection of canine lipomas with BXT-786 coolant, and to assess its impact on lipoma size.

Methods: Ten healthy adult client-owned animals, each with two similarly sized, cytologically confirmed lipomas were enrolled. Lipomas were injected with either BXT-786 coolant or control room temperature 0.

View Article and Find Full Text PDF