A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Disentangling extracellular current of electroactive bacteria with oblique-incidence reflection difference imaging. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Understanding the extracellular electron transfer (EET) process of electroactive bacteria is of great significance. It is critical yet challenging to differentiate the partial currents from direct (DET) and mediated electron transfer (MET) pathways in the integrated EET current. Herein the EET current of model exoelectrogen is successfully disentangled by using spatiotemporally-resolved oblique-incidence reflection difference (OIRD) technique coupled with polyaniline (PANI)-based dual electrode. The PANI film serves as an electron acceptor to translate the charge information into OIRD signals, enabling mapping of EET current. Upon complete reduction of PANI, the local EET current is switched off, and the soluble mediators are forced to discharge on the nearby PANI electrode, enabling measuring of MET current. In such a way, the DET and MET currents are measured and the average currents from each bacterium are quantified. As-reported method enables successful disentangling the EET current and may offer valuable insights to related research.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12313974PMC
http://dx.doi.org/10.1038/s41467-025-62467-6DOI Listing

Publication Analysis

Top Keywords

eet current
20
electroactive bacteria
8
oblique-incidence reflection
8
reflection difference
8
electron transfer
8
current
7
eet
6
disentangling extracellular
4
extracellular current
4
current electroactive
4

Similar Publications