Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Augmented reality (AR) technology overlays digital content onto the real world, in contrast to virtual reality (VR), which immerses users in a fully virtual environment. This fundamental distinction enables AR users to maintain continuous interaction with their physical surroundings while receiving enhanced digital information. In AR system design, optimizing both perspective effects and imaging performance is crucial. However, achieving a wide field of view (FOV), high resolution, and comfortable wearability in a head-mounted display (HMD) remains highly challenging. This paper presents a novel design methodology for a wide-FOV HMD system based on freeform optics and ipsilateral oblique projection. A multi-objective optimization framework, combining the non-dominated sorting genetic algorithm II (NSGA-II) and prior design knowledge, is employed to balance critical parameters such as image quality, weight, and cost. The resulting AR display achieves a full FOV of 75° × 40° and an exit pupil diameter of 14 × 12 mm-representing the widest FOV among comparable systems to date. Moreover, the ipsilateral oblique projection architecture brings the projection lens group closer to the user's head and reduces the tilt angle of the reflective visor, thereby enhancing ergonomic comfort. This configuration also reduces FOV losses due to stitching between intermediate reflective mirrors. The final assembled system demonstrates outstanding overall performance.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.565210DOI Listing

Publication Analysis

Top Keywords

oblique projection
12
head-mounted display
8
ipsilateral oblique
8
development wide-field-of-view
4
wide-field-of-view head-mounted
4
display utilizing
4
utilizing freeform
4
freeform surfaces
4
surfaces oblique
4
projection
4

Similar Publications

Objective: The inferior temporal arteries (ITAs), branches of the posterior cerebral artery (PCA), are critical vascular structures encountered during subtemporal surgical approaches. Anatomical data based on multiphase postmortem computed tomography angiography (MPMCTA) are provided as a tool for preoperative surgical planning to lower the risk of ITA injury.

Methods: Adult (≥18 years) cases that underwent MPMCTA during 2015 to 2023 and whose cause of death did not involve the cerebral circulation were included in the study.

View Article and Find Full Text PDF

Whole-leg radiographs (WLRs) are widely used to assess coronal alignment before total knee arthroplasty (TKA), but may be inaccurate in patients with atypical morphotypes or malrotation. This study evaluated the discrepancy between WLR and 3D computed tomography (CT) scans across coronal plane alignment of the knee (CPAK) morphotypes and introduced a novel projection index-the femoral notch projection ratio (FNPR). In CPAK III knees, 19% of cases exceeded a clinically relevant threshold (>3° difference), prompting investigation of underlying projection factors.

View Article and Find Full Text PDF

Objective: Central tarsal bone (CTB) fractures are challenging to diagnose, and cross-sectional imaging is required for definitive characterization and surgical planning. This retrospective case series aims to provide the first description of high-field (3-T) MRI characteristics of CTB fractures, concurrent pathology, and clinical presentation in 8 performance horses.

Animals: 8 horses (9 limbs) diagnosed with a CTB fracture on high-field MRI at one tertiary referral hospital between 2013 and 2023 were identified via electronic medical records search.

View Article and Find Full Text PDF

Objective: To establish the feasibility of a novel technique for performing carpal stress radiography and to compare carpal angles between standing and sedated stress radiography at 2 applied loads on standard and oblique projections in normal dogs.

Methods: In this prospective, exploratory, analytical study, 4-view standing radiographs were performed at 30% body weight (BW) and 60% BW weightbearing force. Sedated 4-view carpal radiographs were performed utilizing a custom-built positioning device at 2 tensile loads extrapolated from the 30% and 60% BW standing mediolateral radiographs.

View Article and Find Full Text PDF

In engineering practice, liquid droplet impingement typically occurs at an oblique angle relative to the target surface, yet the influence of impact orientation on damage outcomes remains contentious and exhibits target-material dependency. In this paper, a typical single-waterjet-generating technique is applied to liquid impact tests on a unidirectional carbon fiber-reinforced polymer (CFRP) laminate, with special focus on the effects of the impingement angle and the fiber orientation. Finite-element simulation is employed to help reveal the failure mechanism of oblique impacts.

View Article and Find Full Text PDF