A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Comparative study for CT-guided I seed implantation assisted by modified and conventional 3D printing non-coplanar template in malignant tumors. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: This study compared the outcomes of modified three-dimensional printed non-coplanar templates (3DPNCT) with those of conventional 3DPNCT for iodine-125 (I) seed implantation in malignant tumors and analyzed associated technical differences.

Material And Methods: We analyzed patients with malignant tumors undergoing I seed implantation in our department from February 2021 to May 2023. Cases using modified 3DPNCT guidance comprised the experimental group, while those using conventional 3DPNCT formed the control group. All patients underwent identical computed tomography (CT) scanning, preoperative planning, and 3D-printed template creation protocols. The experimental group featured modifiable guide posts enabling intraoperative needle angle/direction adjustments. Pre- and postoperative planning target volume (PTV) and dosimetric parameters included D, D, V, V, conformity index (CI), external index (EI), and homogeneity index (HI) were compared intra- and inter-group.

Results: A total of 70 patients were enrolled, including 35 in the experimental group and 35 in the control group. In the experimental group, pre- and post-operation values for PTV, D, CI and EI, were 61.4(24.9,106.6)cc and 61.6(24.9,106.7)cc, (71.9 ± 16.77) Gy and (65.6 ± 18.0)Gy, 0.7615(0.7102,0.7941) and 0.7780(0.7214,0.8172), 19.0(14.8,25.6)% and 16.1(13.0,28.0)%, respectively, showing a statistically significant difference (P < 0.05). The PTV, D, D, V, CI, EI and HI values before and after the operation in the control group were (69.0 ± 55.0)cc and (69.1 ± 55.0)cc, (124.0 ± 12.4)Gy and (123.1 ± 12.6)Gy, (71.3 ± 13.7)Gy and (66.7 ± 13.5)Gy, (60.1 ± 7.5)% and (58.1 ± 7.8)%, (0.7296 ± 0.0702) and (0.7476 ± 0.0748), (24.6 ± 12.8)% and (21.8 ± 13.6)%, (34.4 ± 7.9)% and (36.5 ± 7.8)%, respectively, with a statistically significant difference. No statistically significant differences were observed in post-operative PTV and dosimetric parameters between the two groups except for D. For the experimental group, the median value of D was 126.27 Gy, and corresponding values were 121.63 Gy for the control group (p < 0.05).

Conclusions: The modified 3DPNCT improved consistency between pre- and post-operative dose parameters in comparison to the conventional 3DPNCT and showed the potential to deliver a higher dose to the tumor. This innovative 3DPNCT provides enhanced adaptability for intraoperative needle adjustments during seed implantation therapies.

Clinical Trial Number: Not applicable.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12308974PMC
http://dx.doi.org/10.1186/s12880-025-01840-9DOI Listing