A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Impact of interface roughness correlation on resonant tunnelling diode variation. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The Nano-Electronic Simulation Software (NESS) features an improved model of Interface Roughness (IR), accounting for correlation lengths in two perpendicular directions and allowing anisotropic roughness. IR in [Formula: see text] Resonant Tunnelling Diodes (RTDs) was investigated using both the previous and improved models, with 4 correlation lengths ([Formula: see text]) ranging from 2.5 nm to 10 nm. For each correlation length, 25 RTD device structures with IR were randomly generated. Device variation was quantified as the standard deviation of the resonant peak current ([Formula: see text]) and the corresponding bias voltage ([Formula: see text]), both extracted from the non-linear RTD current-voltage (IV) characteristics. The improved model resulted in greater variation, increasing standard deviation from 6.2 mV and 9 nA to 24.2 mV and 34.7 nA for [Formula: see text] nm. Standard deviation also roughly doubled as [Formula: see text] increased from 2.5nm to 10nm, increasing from 6.2 mV and 9 nA to 11.7 mV and 18.8 nA for the previous IR model, and from 24.2 mV and 34.7 nA to 38.8 mV and 80.9 nA for the improved IR model. A further study of anisotropic correlation lengths resulted in variation of standard deviations. This paper hence shows the importance of simulating IR with two correlation lengths for future accurate RTD research.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12287518PMC
http://dx.doi.org/10.1038/s41598-025-07720-0DOI Listing

Publication Analysis

Top Keywords

[formula text]
24
correlation lengths
16
improved model
12
standard deviation
12
interface roughness
8
resonant tunnelling
8
242 347
8
correlation
6
[formula
6
text]
6

Similar Publications