98%
921
2 minutes
20
Percutaneous screw placement can treat nondisplaced or scaphoid waist fractures. Screws positioned in areas of highest trabecular density improve fracture stability and bone healing. This study aims to compare the density of six segments of the intact scaphoid bone to facilitate optimal screw positioning. This study compared the density of six segments of the scaphoid bone in 214 intact scans using the 3D Quantitative Imaging (3DQI) Platform. The scaphoid was divided into proximal, middle and distal regions, each with radial and ulnar segments. Densities were measured in Hounsfield units (HU) and compared using a mixed effects model. The proximal pole had the highest density (proximal radial 551 ± 115 HU; proximal ulnar 546 ± 116 HU), followed by the middle, with the distal pole having the lowest density. The proximal segments were significantly denser than the middle and distal segments. Our study suggests a more ulnar starting point in the distal pole for retrograde percutaneous screw placement, to maximise engagement of the highest trabecular bone density. For the antegrade approach, the proximal pole demonstrates consistently uniform density, permitting screw placement based on fracture plane; however, if possible, the ulnar segment of the distal pole should be engaged.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1142/S2424835525500560 | DOI Listing |
Medicine (Baltimore)
September 2025
Department of Neurological Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
The cervicothoracic junction (CTJ) presents a surgical challenge due to its transitional nature from mobile to rigid segments. Therefore, the biomechanical characteristics of this transitional zone must be taken into consideration during instrumentation. This study aimed to determine the efficacy of the cervical pedicle screw placement (CPS) combined with 5.
View Article and Find Full Text PDFSurg Radiol Anat
September 2025
Orthopaedics and Traumathology Department, ULS São João, Porto, Portugal.
Purpose: Pelvic ring fractures involving the iliopubic rami can cause functional impairment. Percutaneous retrograde fixation is a less invasive procedure when compared to traditional open approaches, however precise anatomical knowledge is crucial for safe screw placement. This study aims to describe the morphology of the iliopubic rami, define a safety corridor for percutaneous screw fixation, specially focusing on the relationships between the iliopubic rami and neurovascular structures.
View Article and Find Full Text PDFJ Vis Exp
August 2025
Tianjin Union Medical Center, The First Affiliated Hospital of Nankai University;
Posterior lumbar screw fixation is the most common surgical method for lumbar disc herniation, but patients often face multiple complications postoperatively. The occurrence of screw track loosening can lead to fusion failure and even life-threatening screw track extrusion. However, there is currently a lack of animal models specifically targeting changes in the screw track following lumbar screw fixation.
View Article and Find Full Text PDFInt J Oral Implantol (Berl)
September 2025
Purpose: To evaluate changes in implant stability quotient values of hydrophilic tissue-level implants over time, and to investigate the influence of local factors on variations in these values.
Methods: Fifty tapered, self-tapping, tissue-level implants with a hydrophilic surface were placed and monitored for 12 months. Implant stability quotient values were recorded at the time of insertion (T0) and monthly thereafter for 12 months.
Front Surg
August 2025
Department of Orthopedics, The First Hospital of Jilin University, Changchun, Jilin, China.
Background: Acetabular reconstruction is often challenging in revision hip arthroplasty, especially in the face of moderate to severe acetabular bone deficiency. In some severe bone defects, double-metal tantalum cups can improve the contact area between bone and implants, increase the surface area for bone ingrowth, and better restore the anatomical position of the acetabulum. Furthermore, with a good press-fit, the auxiliary screw has a minimal effect on acetabular cup stability.
View Article and Find Full Text PDF