Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

NaI(Tl) based standing geometry whole body counter, Quick Scan Whole Body Monitor (QSWBM), has been used for in-vivo detection of high-energy photon emitters in various laboratories across India. Conventionally, the Indian reference BOMAB phantom (BOMAB-I) is being used for the periodic calibration of QSWBM. For calibration purposes, various monitoring laboratories follow diverse source configurations in a phantom, such as uniform distribution, axial cavity distribution, and central axial cavity distribution, depending on the source availability and phantom type. In the present study, simulations using FLUKA code were performed for QSWBM using numerical BOMAB-I phantom for uniform and various axial cavity distributions. The results from different source configurations were compared to understand the optimum number of sources to be procured for accurate calibration of a standing geometry whole body counter using BOMAB-I phantom. The study demonstrated that the axial source based calibration can be performed effectively using BOMAB-I phantom with a minimum of one source instead of a configuration in which multiple sources are distributed along the entire axial cavity. The deviation of QSWBM calibration in axial source configurations as compared to uniform source distribution was found to be 9-13 % for various energies. This suggests that uniform source distribution in BOMAB-I should be preferred over axial source distribution to perform more accurate calibration for QSWBM. An experimental validation of QSWBM calibration using single source methodology was also carried out, and deviations <10 % were observed for Cs and Co emissions.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.apradiso.2025.112055DOI Listing

Publication Analysis

Top Keywords

source configurations
16
axial cavity
16
qswbm calibration
12
bomab-i phantom
12
axial source
12
source distribution
12
source
11
calibration
8
quick scan
8
scan body
8

Similar Publications

In-line multi-wavelength non-destructive pharma quality monitoring with ultrabroadband carbon nanotubes photo-thermoelectric imaging scanners.

Light Sci Appl

September 2025

Department of Electrical, Electronic, and Communication Engineering, Faculty of Science and Engineering, Chuo University, 1-13-27 Kasuga, Bunkyo-ku, Tokyo, 112-8551, Japan.

While non-destructive in-line monitoring at manufacturing sites is essential for safe distribution cycles of pharmaceuticals, efforts are still insufficient to develop analytical systems for detailed dynamic visualisation of foreign substances and material composition in target pills. Although spectroscopies, expected towards pharma testing, have faced technical challenges in in-line setups for bulky equipment housing, this work demonstrates compact dynamic photo-monitoring systems by selectively extracting informative irradiation-wavelengths from comprehensive optical references of target pills. This work develops a non-destructive in-line dynamic inspection system for pharma agent pills with carbon nanotube (CNT) photo-thermoelectric imagers and the associated ultrabroadband sub-terahertz (THz)-infrared (IR) multi-wavelength monitoring.

View Article and Find Full Text PDF

Background: Electronic health records (EHRs) are a cornerstone of modern health care delivery, but their current configuration often fragments information across systems, impeding timely and effective clinical decision-making. In gynecological oncology, where care involves complex, multidisciplinary coordination, these limitations can significantly impact the quality and efficiency of patient management. Few studies have examined how EHR systems support clinical decision-making from the perspective of end users.

View Article and Find Full Text PDF

On-Chip Emitter-Coupled Meta-Optics for Versatile Photon Sources.

Phys Rev Lett

August 2025

University of Southern Denmark, Centre for Nano Optics, Campusvej 55, Odense M DK-5230, Denmark.

Controlling the spontaneous emission of nanoscale quantum emitters (QEs) is crucial for developing advanced photon sources required in many areas of modern nanophotonics, including quantum information technologies. Conventional approaches to shaping photon emission are based on using bulky configurations, while approaches recently developed in quantum metaphotonics suffer from limited capabilities in achieving desired polarization states and directionality, failing to provide on-demand photon sources tailored precisely to technological needs. Here, we propose a universal approach to designing versatile photon sources using on-chip QE-coupled meta-optics that enable direct transformations of QE-excited surface plasmon polaritons into spatially propagating photon streams with arbitrary polarization states, directionality, and amplitudes via both resonance and geometric phases supplied by scattering meta-atoms.

View Article and Find Full Text PDF

[Modern view on the mechanism of traffic injury in collision of moving vehicle and pedestrian].

Sud Med Ekspert

September 2025

Bureau of Forensic Medical Examination of the Department of Health Care of the City of Moscow, Moscow, Russia.

The article considers the main phases of traffic injury (TI) described by A.A. Solokhin in 1968 and their modern application in forensic medical and automotive examination.

View Article and Find Full Text PDF

Approaches to stereoselective 1,1'-glycosylation.

Beilstein J Org Chem

August 2025

Department of Natural Sciences and Sustainable Resources, Institute of Organic Chemistry, BOKU University, 1190 Vienna, Austria.

Nonreducing disaccharides are prevalent in non-mammalian glycans and glycolipids, serving as pivotal structural components in mycobacterial glycans, microbial oligosaccharide and nucleoside antibiotics, as well as biologically active mimetics of bacterial pathogen-associated molecular patterns (PAMPs). As integral components of PAMPs, 1,1'-linked disaccharide-containing biomolecules play important roles in host-pathogen interactions, cellular signaling, and pathogenesis. Accessing complex biomolecules containing nonreducing disaccharides is often hindered by difficulties in isolating them from natural sources, which can result in impure or degraded products, particularly when sensitive functional groups are involved.

View Article and Find Full Text PDF