Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objectives: In general, Medicare pays for emergency ground ambulance services when a patient is transported to the nearest emergency department (ED) or other select facilities. As state and local agencies strive to provide high quality person-centered emergency care in locations outside the ED, there is a need for a reliable and valid prehospital quality measure to ensure patient safety. The Centers for Medicare and Medicaid Innovation Center's Emergency Triage, Treat and Transport (ET3) Model created a unique opportunity to develop a quality measure for ambulance organizations to measure safe and effective prehospital care. Our objective was to develop and validate the Risk Adjusted Post-Ambulance Provider Triage ED Visit Rate Measure.

Methods: The measure was developed using 2021-2023 Medicare Part B fee-for-service administrative and claims data from 67 ambulance organizations that participated in the ET3 Model, triaging patients using predetermined clinical protocols. The measure cohort included patients that were either transported to an alternative destination (TAD), such as urgent care, or provided treatment in place (TIP). The measure outcome was met if the patient subsequently had an ED visit or died within three days of a TAD/TIP encounter, as an inverse measure, lower is better. We calculated a risk-adjusted measure score using a hierarchical generalized linear model approach, adjusting for patient-level variables and calculating model and measure performance. Finally, we assessed measure face validity and construct validity. To ensure measure reliability, some results were examined using a minimum case threshold of 20 TAD/TIP encounters by each ambulance organization.

Results: Among the 22 ambulance organizations that met the minimum case volume threshold, the mean, SD measure score was 20.3 (5.3), ranging from 11.6 to 35.4. The mean (SD) reliability signal-to-noise ratio was 0.791 (0.124). Nine of 11 (82%) members of an interested party consensus group provided a positive vote of face validity. Construct validity was demonstrated by identifying an anticipated negative correlation with three relevant prehospital measures.

Conclusions: The Risk Adjusted Post-Ambulance Provider Triage ED Visit Rate Measure is a reliable and valid measure that fills a critical gap in assessing patient safety in prehospital care in the United States.

Download full-text PDF

Source
http://dx.doi.org/10.1080/10903127.2025.2535574DOI Listing

Publication Analysis

Top Keywords

measure
15
ambulance organizations
12
administrative claims
8
reliable valid
8
quality measure
8
patient safety
8
et3 model
8
prehospital care
8
risk adjusted
8
adjusted post-ambulance
8

Similar Publications

In routine forensic chemical casework where measurements are performed on reference materials, determination of measurement uncertainty is described in several guidelines. The proposed methods often have the drawback that they are not derived from a statistical framework and may lead to conservative confidence intervals. Furthermore, the formulas involved may vary considerably for different types of reference material.

View Article and Find Full Text PDF

Self-efficacy and anatomical knowledge have been shown to be important in the development of medical students. Validated instruments designed to measure the construct of anatomical self-efficacy during the clinical years of medical school are limited. In this study, the Anatomical Self-Efficacy Instrument for Clinical Clerkships (ASEI-CC) was developed, and evidence for the reliability of the scores and the validity of the interpretations of the scores was gathered.

View Article and Find Full Text PDF

Background And Purpose: To review the existing evidence on multiple timepoint assessments of optic nerve sheath diameter (ONSD) as an indicator of intraindividual variation of intracranial pressure (ICP).

Methods: A systematic search identified studies assessing intraindividual variation in ICP through multiple timepoint measurements of ONSD using ultrasonography. Meta-analysis of studies assessing intraindividual correlation coefficients between ONSD and ICP was performed using a random effects model, and we calculated the weighted correlation coefficient for the expected change in ICP associated with variations in ONSD.

View Article and Find Full Text PDF