Article Abstract

Objective: To evaluate the cost-effectiveness of AI-assisted digital mammography (AI-DM) compared to conventional biennial breast cancer digital mammography screening (cDM) with double reading of screening mammograms, and to investigate the change in cost-effectiveness based on four different sub-strategies of AI-DM.

Materials And Methods: A decision-analytic state-transition Markov model was used to analyse the decision of whether to use cDM or AI-DM in breast cancer screening. In this Markov model, one-year cycles were used, and the analysis was performed from a healthcare perspective with a lifetime horizon. In the model, we analysed 1000 hypothetical individuals attending mammography screenings assessed with AI-DM compared with 1000 hypothetical individuals assessed with cDM.

Results: The total costs, including both screening-related costs and breast cancer-related costs, were €3,468,967 and €3,528,288 for AI-DM and cDM, respectively. AI-DM resulted in a cost saving of €59,320 compared to cDM. Per 1000 individuals, AI-DM gained 10.8 quality-adjusted life years (QALYs) compared to cDM. Gained QALYs at a lower cost means that the AI-DM screening strategy was dominant compared to cDM. Break-even occurred at the second screening at age 42 years.

Conclusion: This analysis showed that AI-assisted mammography for biennial breast cancer screening in a Swedish population of women aged 40-74 years is a cost-saving strategy compared to a conventional strategy using double human screen reading. Further clinical studies are needed, as scenario analyses showed that other strategies, more dependent on AI, are also cost-saving.

Key Points: Question To evaluate the cost-effectiveness of AI-DM in comparison to conventional biennial breast cDM screening. Findings AI-DM is cost-effective, and the break-even point occurred at the second screening at age 42 years. Clinical relevance The implementation of AI is clearly cost-effective as it reduces the total cost for the healthcare system and simultaneously results in a gain in QALYs.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00330-025-11821-9DOI Listing

Publication Analysis

Top Keywords

digital mammography
12
biennial breast
12
breast cancer
12
compared cdm
12
ai-dm
9
cost-effectiveness ai-assisted
8
ai-assisted digital
8
evaluate cost-effectiveness
8
ai-dm compared
8
compared conventional
8

Similar Publications

ObjectiveTo study the implications of implementing artificial intelligence (AI) as a decision support tool in the Norwegian breast cancer screening program concerning cost-effectiveness and time savings for radiologists.MethodsIn a decision tree model using recent data from AI vendors and the Cancer Registry of Norway, and assuming equal effectiveness of radiologists plus AI compared to standard practice, we simulated costs, effects and radiologist person-years over the next 20 years under different scenarios: 1) Assuming a €1 additional running cost of AI instead of the €3 assumed in the base case, 2) varying the AI-score thresholds for single vs. double readings, 3) varying the consensus and recall rates, and 4) reductions in the interval cancer rate compared to standard practice.

View Article and Find Full Text PDF

Mammography is a primary method for early screening, and developing deep learning-based computer-aided systems is of great significance. However, current deep learning models typically treat each image as an independent entity for diagnosis, rather than integrating images from multiple views to diagnose the patient. These methods do not fully consider and address the complex interactions between different views, resulting in poor diagnostic performance and interpretability.

View Article and Find Full Text PDF

Background The optimal surgical management of human epidermal growth factor receptor 2 (HER2)-positive breast cancer with calcifications remains controversial, particularly when pathologic complete response (pCR) is suspected. Purpose To identify factors associated with pCR after neoadjuvant chemotherapy in patients with HER2-positive breast cancer and assess whether calcifications affect the performance of radiologic complete response (rCR) at MRI for predicting pCR. Materials and Methods This retrospective study included patients with HER2-positive breast cancer who received neoadjuvant docetaxel, carboplatin, trastuzumab, and pertuzumab and underwent surgery between January 2021 and October 2023.

View Article and Find Full Text PDF

Purpose: To develop and validate a deep learning-based model for automated evaluation of mammography phantom images, with the goal of improving inter-radiologist agreement and enhancing the efficiency of quality control within South Korea's national accreditation system.

Materials And Methods: A total of 5,917 mammography phantom images were collected from the Korea Institute for Accreditation of Medical Imaging (KIAMI). After preprocessing, 5,813 images (98.

View Article and Find Full Text PDF

Metastatic involvement (MB) of the breast from extramammary malignancies is rare, with an incidence of 0.09-1.3% of all breast malignancies.

View Article and Find Full Text PDF