Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cjca.2025.07.007DOI Listing

Publication Analysis

Top Keywords

dedicated device
4
device safe
4
safe aortic
4
aortic prosthesis
4
prosthesis crossing
4
crossing easycross
4
easycross catheter
4
dedicated
1
safe
1
aortic
1

Similar Publications

ObjectiveThis study aims to determine the outcomes of nickel allergic patients who underwent a trial of forearm arterial stenting with a nickel-based stent, with follow-up to assess for an allergic reaction. In the absence of adverse effects, patients had their intracranial aneurysm treatment with a nickel-based cerebrovascular device.MethodsA retrospective analysis was performed on patients who had an allergy to nickel, with an intracranial aneurysm who underwent treatment with a permanently implanted nickel-containing device.

View Article and Find Full Text PDF

Spanish cardiac catheterization and coronary intervention registry. 34 official report of the Interventional Cardiology Association of the Spanish Society of Cardiology (1990-2024).

Rev Esp Cardiol (Engl Ed)

September 2025

Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV), Instituto de Salud Carlos III, Madrid, España; Servicio de Cardiología, Hospital Clínico de Santiago de Compostela, Santiago de Compostela, España.

Introduction And Objectives: This report presents the 2024 activity data from the Interventional Cardiology Association of the Spanish Society of Cardiology (ACI-SEC).

Methods: All interventional cardiology laboratories in Spain were invited to complete an online survey. Data analysis was conducted by an external company and then reviewed and presented by the ACI-SEC board.

View Article and Find Full Text PDF

The effect of human bone morphology on sawing forces.

J Mech Behav Biomed Mater

September 2025

Department of Biomechanical Engineering, Faculty of Engineering Technology, University of Twente, Enschede, 7522 NB, the Kingdom of the Netherlands. Electronic address:

In orthopaedic surgical procedures, bone cutting is often performed with an oscillating saw. Achieving an optimal cut requires high accuracy, low temperature, minimal surgeon effort, and time efficiency, all of which may be influenced by the forces applied on the sawing device, and the microstructure of the cut bone. The relation between bovine bone microstructure and sawing forces has been studied.

View Article and Find Full Text PDF

Background: Dedicated radiofrequency (RF) needles and wires for transseptal puncture (TSP) achieve better outcomes vs. electrified open-ended needles and guidewires due to optimized electrode design and energy delivery. This study benchmarked TSP performance between the dedicated VersaCross wire system (VC; Boston Scientific) and an electrified guidewire with an alternative electrode configuration similar to commercially available devices.

View Article and Find Full Text PDF

We present a case of successful transfemoral transcatheter aortic valve replacement for a rare quadricuspid aortic valve with pure aortic regurgitation. Procedural challenges included identifying the annular plane, determining the appropriate deployment view, annular sizing, the absence of annular calcium, and the lack of a dedicated transcatheter device for pure aortic regurgitation.

View Article and Find Full Text PDF