A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Direct determination of rare earth elements in atmospheric precipitation using a membrane desolvation ICP-MS/MS with NO as the reaction gas. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Analyzing rare earth elements (REEs) in atmospheric precipitation can reveal their sources and migration patterns. However, their direct determination in atmospheric precipitation using ICP-MS/MS remains challenging owing to low (sub-ng L) levels and mass spectral interference. This study established a reliable ICP-MS/MS method using a membrane desolvation system to enhance the sensitivity of REEs detections and employing NO as the reaction gas to eliminate spectral interference for the direct measurement of REEs in atmospheric precipitation. The production rates of REE monoxides were significantly enhanced when using NO as the reaction gas instead of O. In particular, the yield of EuO increased to 64.9%, while that of YbO increased to 39.5%. A regular 10% signal suppression of REE was observed in the presence of matrix using membrane desolvation and employing Re as an internal standard effectively improved the results by >98%. The instrumental detection limits of the proposed method ranged from 0.001 ng L for Lu to 0.022 ng L for Nd. The results for REEs in the certified reference material (SLRS-6) at a 1 : 10 dilution was consistent with the values reported in the literature. Thus, the proposed method was employed to analyze atmospheric precipitation samples. The accuracy of the results demonstrated that this method has the potential for routinely measuring sub ng L levels of REEs in freshwater samples, offering advantages regarding sample throughput and reduced handling.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12261074PMC
http://dx.doi.org/10.1039/d5ra02544cDOI Listing

Publication Analysis

Top Keywords

atmospheric precipitation
20
membrane desolvation
12
reaction gas
12
direct determination
8
rare earth
8
earth elements
8
rees atmospheric
8
spectral interference
8
proposed method
8
atmospheric
5

Similar Publications