98%
921
2 minutes
20
Background: Temporomandibular disorders (TMDs) are challenging to manage due to their multifactorial nature. As with other joints, the function of temporomandibular joint (TMJ) is influenced by proprioception, making it an essential factor in TMD management. However, previous studies on the joint position error (JPE) in TMD patients lacked a proper diagnosis and reliability assessment.
Objectives: The aim of the present study was to develop a reliable JPE test in healthy adults as a foundation for future evaluation in TMD patients.
Material And Methods: Two examiners conducted the JPE assessment, utilizing a methodology encompassing between-days intra-rater and within-day inter-rater reliability assessments. A total of 22 healthy participants (7 men and 15 women) with a mean unassisted mouth opening of 46 ±5 mm were recruited. The evaluation targeted specific distances (10 mm, 20 mm and 30 mm) within the participants' mouth opening range, with proprioceptive accuracy evaluated through the measurement of the absolute error (AE) and the constant error (CE).
Results: The CE was consistently lower than AE across all the targeted distances, although with higher standard deviations. Intra-rater reliability varied across the distances, with poor reliability observed for AE at 10 mm, moderate reliability for CE at 10 mm, good reliability for both AE and CE at 20 mm, and moderate reliability for both AE and CE at 30 mm. Inter-rater reliability was moderate at 10 mm and good at 20 mm for both AE and CE, with equally moderate reliability levels at 30 mm.
Conclusions: The 20 mm target distance demonstrated good intraand inter-rater reliability, warranting its evaluation in patients with TMDs in the subsequent investigation phase.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.17219/dmp/193072 | DOI Listing |
Glob Ment Health (Camb)
July 2025
Institute of Psychiatry, Psychology and Neuroscience, King's College London, London, UK.
Problem-solving therapy (PST) is a brief psychological intervention often implemented for depression. Currently, there are no tools with well-evidenced reliability to measure PST fidelity. This pilot study aimed to measure the inter-rater reliability and agreement of the blem-Slving Therapy idelity (PROOF) scale, comprising binary 14-item adherence and an 8-item competence subscales.
View Article and Find Full Text PDFFluids Barriers CNS
September 2025
Department of Medical Sciences, Neurology, Uppsala University, Uppsala, Sweden.
Background: Idiopathic normal pressure hydrocephalus (iNPH) predominantly manifests with gait disturbances, yet clinical assessments are vulnerable to confirmation bias, particularly post-shunt surgery. Blinded video evaluations are a method to enhance objectivity in gait assessment, but their reliability has never been systematically investigated. The aim was to evaluate the inter-rater reliability of blinded gait assessments in iNPH patients and to investigate how these assessments correlate with the Hellström iNPH scale and patient-reported health status following shunt surgery.
View Article and Find Full Text PDFEur Radiol Exp
September 2025
Center for MR-Research, University Children's Hospital Zurich, University of Zurich, Zurich, Switzerland.
Background: Fetal MRI is increasingly used to investigate fetal lung pathologies, and super-resolution (SR) algorithms could be a powerful clinical tool for this assessment. Our goal was to investigate whether SR reconstructions result in an improved agreement in lung volume measurements determined by different raters, also known as inter-rater reliability.
Materials And Methods: In this single-center retrospective study, fetal lung volumes calculated from both SR reconstructions and the original images were analyzed.
Zhonghua Jie He He Hu Xi Za Zhi
September 2025
Department of Respiratory and Critical Care Medicine, the Second Affiliated Hospital of Nanjing University of Chinese Medicine, Nanjing 210009, China.
Severe pneumonia, as a critical and prevalent condition of the respiratory system, poses a significant threat to patient survival and health outcomes. This article focuses on the similarities and differences between community-acquired pneumonia (CAP) and hospital-acquired pneumonia (HAP)/ventilator-associated pneumonia (VAP). There is significant divergence in the predominant pathogens between severe community-acquired pneumonia (SCAP) and HAP/VAP.
View Article and Find Full Text PDFJ Forensic Leg Med
August 2025
Laboratory of Criminalistics, Adam Mickiewicz University in Poznań, al. Niepodległości 53, Poznań 61-714, Poland; Center for Advanced Technologies, Adam Mickiewicz University in Poznań, ul. Uniwersytetu Poznańskiego 10, Poznań 61-614, Poland.
This study examines the reliability of fingerprint experts in assessing the individualization value of minutiae during the analysis of latent fingerprint traces. Despite the widespread use of fingerprint evidence in criminal investigations, growing concerns about examiner variability and the lack of verification protocols have prompted critical scrutiny of forensic practices. In this study, 30 Polish fingerprint experts were asked to identify and evaluate seven minutiae in two fingerprint traces of differing quality.
View Article and Find Full Text PDF