Transfemoral transcatheter aortic valve-in-valve implantation using endoconduit in a patient with right-sided aortic arch and complex vascular anatomy: a case report.

Eur Heart J Case Rep

Department of Cardiology, Asia Medical Group, Sapporo Heart Center, Sapporo Cardio Vascular Clinic, North 49, East 16, 8-1, Higashi Ward, Sapporo, Hokkaido 007-0849, Japan.

Published: July 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: The number of transcatheter aortic valve implantation (TAVI) procedures has increased significantly and now includes younger and higher-risk surgical patients. As early-generation transcatheter heart valves (THVs) continue to degrade over time, the incidence of structural valve deterioration (SVD) is increasing, requiring more complex valve-in-valve (TAV-in-TAV) procedures.

Case Summary: We present a case of SVD of a THV, resulting in severe aortic regurgitation in an 88-year-old female with decompensated heart failure. Eight years prior, the patient had undergone TAVI with SAPIEN XT 23 mm via the transapical approach because of severe calcified stenosis of the lower extremity arteries and extreme tortuosity from the arch to the descending aorta and abdominal aortic aneurysm, right-sided aortic arch. Considering the patient's condition and access route, we performed emergency transfemoral TAV-in-TAV using a 23 mm SAPIEN3 Ultra RESILIA. The endoconduit technique successfully facilitated sheath passage. The valve was implanted without complications. The procedure was successful, resulting in only trace paravalvular regurgitation. The post-operative effective orifice area was 1.80 cm² (indexed EOA: 1.32 cm²/m²). The Doppler Velocity Index was 0.59, suggesting no significant patient-prosthesis mismatch.

Discussion: Vascular anomalies often restrict the choice of a safe access route in TAVI procedures. The endoconduit technique provides a minimally invasive solution for accessing complex iliac arteries. This case illustrates the importance of selecting the appropriate sheath, utilising endoconduit, and employing various procedural techniques to manage complex anatomies and ensure successful outcomes in TAV-in-TAV procedures.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12255226PMC
http://dx.doi.org/10.1093/ehjcr/ytaf315DOI Listing

Publication Analysis

Top Keywords

transcatheter aortic
8
right-sided aortic
8
aortic arch
8
tavi procedures
8
access route
8
endoconduit technique
8
aortic
6
transfemoral transcatheter
4
aortic valve-in-valve
4
valve-in-valve implantation
4

Similar Publications

Comparison of short- and long-term outcomes between transcatheter and surgical aortic valve replacement for bicuspid aortic valve stenosis: a systematic review and meta-analysis.

Int J Surg

September 2025

Department of Cardiovascular Surgery, The Affiliated Hospital, Southwest Medical University, Metabolic Vascular Diseases Key Laboratory of Sichuan Province, Key Laboratory of Cardiovascular Remodeling and Dysfunction, Luzhou, Sichuan, PR China.

Objective: This meta-analysis aimed to compare the perioperative safety and efficacy of transcatheter aortic valve replacement (TAVR) versus surgical aortic valve replacement (SAVR) in bicuspid aortic valve (BAV) stenosis.

Methods: We systematically analyzed studies from PubMed, Cochrane Library, Embase, and CNKI comparing TAVR and SAVR in BAV stenosis. Outcomes included postoperative mortality, complications, all-cause survival, and freedom from stroke.

View Article and Find Full Text PDF

Background: Mitral regurgitation (MR) may rarely worsen after transcatheter aortic valve implantation (TAVI) due to mechanical interference from the transcatheter heart valve (THV). Standard surgical approaches in these cases are often challenging due to anatomical constraints. Thus, there is a need for the development of effective alternatives to address this issue.

View Article and Find Full Text PDF

Rapid Atrial Pacing After TAVI for Pacemaker Prediction.

Rev Cardiovasc Med

August 2025

Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel, European Reference Networks Guard-Heart, 1090 Brussels, Belgium.

Despite continued advancements in transcatheter aortic valve implantation (TAVI) techniques, the incidence of permanent pacemaker implantation (PPI) remains substantial. Established predictors of PPI include advanced age, pre-existing electrocardiographic conduction abnormalities, prosthetic valve type, implantation depth, and anatomical parameters, such as membranous septum length, which are currently under active investigation. In routine clinical practice, the management strategy often involves the temporary placement of a transvenous pacemaker lead, followed by a period of observation.

View Article and Find Full Text PDF

Background: Differences between female and male patients may influence the outcomes of transcatheter aortic valve replacement (TAVR). However, knowledge regarding known sex differences in TAVR procedures among Chinese people remains limited. Therefore, this study aimed to investigate the impact of sex-related differences on reverse left ventricular (LV) remodeling following TAVR in the Chinese population.

View Article and Find Full Text PDF

Background: Degeneration of surgical bioprosthetic aortic valves is increasingly common. Redo surgical aortic valve replacement carries substantial morbidity and mortality, particularly in elderly or high-risk patients. Valve-in-valve (ViV) transcatheter aortic valve implantation (TAVI) has become an established alternative, though data on the performance of self-expanding Portico and Navitor valves remain limited.

View Article and Find Full Text PDF