To investigate the anchorage performance of an innovative assembled joint with large-diameter steel bar grout lapping in a concrete reserved hole, the effects of anchorage length and high-strength grouting material types on the failure mode, load-displacement curve, ultimate bond strength and strain variation were analyzed through the pull-out tests of 15 specimens. On this basis, the calculation formulae of critical and ultimate anchorage length were established and the applicability was verified, and then the recommended value of minimum anchorage length was provided. The results showed that the failure modes included splitting-steel bar pull-out failure and UHPC-concrete interface failure. With the increase in anchorage length, the bond strength showed a trend of increasing first and then decreasing. Increasing the grouting material strength can effectively improve the bond performance. When the anchored steel bar is HRB400 with a diameter not less than 20 mm, the recommended minimum anchorage length is 15.0~18.3. When the grouting material strength is larger than or equal to 100 MPa, the anchorage length should not be less than 15.0.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12250788 | PMC |
http://dx.doi.org/10.3390/ma18132950 | DOI Listing |
Proc Natl Acad Sci U S A
September 2025
Colorado State University, Department of Forest and Rangeland Stewardship, Fort Collins, CO 80523.
The streams of Alaska's Brooks Range lie within a vast (~14M ha) tract of protected wilderness and have long supported both resident and anadromous fish. However, dozens of historically clear streams have recently turned orange and turbid. Thawing permafrost is thought to have exposed sulfide minerals to weathering, delivering iron and other potentially toxic metals to aquatic ecosystems.
View Article and Find Full Text PDFEndosc Int Open
August 2025
Gastroenterology, CHU Nice, Nice, France.
Background And Study Aims: Migration remains a frequent and challenging situation following esophageal stent placement. The aims of this study were to evaluate efficiency and safety of a new anchorage technique using through-the-scope (TTS) clips to prevent esophageal stent migration.
Patients And Methods: This was a retrospective case-control analysis of a prospective, monocentric database.
BMC Oral Health
August 2025
Faculty of Dentistry, Department of Orthodontics, Gazi University, Ankara, Turkey.
Objectives: The aim of this retrospective cohort study was to compare the total duration of Class II malocclusion treatment with hybrid pendulum vs. buccal interradicular miniscrew supported distalization mechanics followed by fixed appliances. Molar distalization duration and end-of-the-treatment changes were also compared.
View Article and Find Full Text PDFCureus
July 2025
Department of Orthodontics, Geetanjali Dental and Research Institute, Udaipur, IND.
Introduction Orthodontic treatment often involves first premolar extraction and anterior tooth retraction to achieve aesthetic and functional harmony in bimaxillary protrusion cases. However, excessive retraction may cause complications such as root resorption and bone loss. This study aimed to evaluate morphometric changes in anterior mandibular alveolar bone and root length during retraction of the mandibular incisors in patients with class I bimaxillary protrusion using cone-beam computed tomography (CBCT).
View Article and Find Full Text PDFClin Adv Periodontics
August 2025
Private Practice, Bari, Italy.
Background: This clinical study presents a novel technique for basal bone anchorage, a surgical approach designed for immediate loading in the atrophic maxilla, specifically in Cawood Class VI cases. By leveraging the structural integrity of basal bone, this method eliminates the need for invasive bone grafting procedures, reducing patient morbidity, shortening treatment timelines, and enhancing overall patient acceptance.
Methods: A single-arm clinical investigation, involving a carefully selected cohort of seven patients, assessed the feasibility, functional outcomes, and implant stability over a 24-month period.