98%
921
2 minutes
20
Bone screws are used in orthopaedic surgery for fracture fixation. Correctly torquing the screws is important for fixation quality. Over-tightening may strip the threads, while under-tightening may result in loosening over time. This paper focuses on testing an approach where strength is estimated using screw insertion data from torque and rotation sensors, and stripping torque is predicted based on this strength. A common type of bone screw was inserted until stripping 10 times each into 8 types of polyurethane surrogate for bone. The torque-rotation data from the insertion was used to identify the material strength and estimate the stripping torque and compared with the experimental maximum torque. A good relationship was found between the estimated/predicted and true stripping torques (r = 0.926, 95% confidence interval (C.I.) [0.886, 0.952]), with a mean error of 18%. Additionally, the intermediate identified strength values were found to be highly correlated with the data-sheet values for the materials (r = 0.977, 95% C.I. [0.964, 0.985]). These outcomes demonstrate the viability and significance of this concept in general, although more development and testing is required for broad clinical applicability; such tests would be extended for more types of bone screws and use a large set of human bone samples to better reflect the natural variability.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12252061 | PMC |
http://dx.doi.org/10.3390/s25133863 | DOI Listing |
J Craniofac Surg
September 2025
Division of Ophthalmic Plastic and Reconstructive Surgery, Sadik Eratik Eye Institute, Haydarpasa Numune Education and Research Hospital, University of Health Sciences.
Orbital floor fractures can lead to enophthalmos and diplopia, often requiring surgical intervention to restore orbital volume. Autologous iliac bone grafts are commonly used due to their biocompatibility and mechanical stability, but achieving adequate fixation remains a challenge. Traditional fixation methods, such as plates and screws, may introduce risks of foreign body reactions, graft displacement, and surgical morbidity.
View Article and Find Full Text PDFMedicine (Baltimore)
September 2025
Department of Neurological Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
The cervicothoracic junction (CTJ) presents a surgical challenge due to its transitional nature from mobile to rigid segments. Therefore, the biomechanical characteristics of this transitional zone must be taken into consideration during instrumentation. This study aimed to determine the efficacy of the cervical pedicle screw placement (CPS) combined with 5.
View Article and Find Full Text PDFSurg Radiol Anat
September 2025
Orthopaedics and Traumathology Department, ULS São João, Porto, Portugal.
Purpose: Pelvic ring fractures involving the iliopubic rami can cause functional impairment. Percutaneous retrograde fixation is a less invasive procedure when compared to traditional open approaches, however precise anatomical knowledge is crucial for safe screw placement. This study aims to describe the morphology of the iliopubic rami, define a safety corridor for percutaneous screw fixation, specially focusing on the relationships between the iliopubic rami and neurovascular structures.
View Article and Find Full Text PDFJ Vis Exp
August 2025
Tianjin Union Medical Center, The First Affiliated Hospital of Nankai University;
Posterior lumbar screw fixation is the most common surgical method for lumbar disc herniation, but patients often face multiple complications postoperatively. The occurrence of screw track loosening can lead to fusion failure and even life-threatening screw track extrusion. However, there is currently a lack of animal models specifically targeting changes in the screw track following lumbar screw fixation.
View Article and Find Full Text PDFClin Exp Dent Res
October 2025
Drug Applied Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.
Objectives: This umbrella meta-analysis aimed to answer the clinical question: Do mini-screws and micro-implants improve specific orthodontic outcomes such as intermolar width, interpremolar width, suture expansion, molar movement, and skeletal width compared to conventional anchorage methods?
Materials And Methods: A systematic search was performed in PubMed, Scopus, ISI Web of Science, and Google Scholar up to October 2024. Systematic reviews and meta-analyses on mini-screws and micro-implants in orthodontic treatment were included. Methodological quality was assessed using AMSTAR 2, and a random-effects model was used to calculate effect sizes (ESs) and 95% confidence intervals (CIs).