[Comparison of magnetic resonance images of the temporomandibular joint using different coils].

Zhonghua Kou Qiang Yi Xue Za Zhi

Shanxi Temporomandibular Joint Diagnostic and Treatment Center, Cultivation Base of Shanxi Key Laboratory for Oral and Maxillofacial Repair, Reconstruction and Regeneration, Jinzhong 030600, China.

Published: July 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

To explore and compare the clinical application value of 8-channel head phased-array coil, an 8-channel temporomandibular joint (TMJ)-specific surface coil, and a single-channel surface coil in TMJ MRI examinations. A total of 600 temporomandibular disorders (TMD) patients (1 200 joints) who underwent TMJ MRI examination in the First People's Hospital of Jinzhong from June 2020 to January 2025 were retrospectively screened. Based on inclusion/exclusion criteria, 120 TMD patients (240 joints) with closed-mouth oblique sagittal proton density weighted imaging (OSag PDWI), coronal T2 fat-suppression weighted imaging (OCor fs T2WI) and open-mouth oblique sagittal proton density weighted imaging (OSag PDWI) were included. Patients were divided into groups A, B, and C, with 40 cases in each group. Group A (31female, 9male, median age 24 years old), underwent 8-channel head phased-array coil imaging. Group B (29 female, 11male, median age 23.5 years old) underwent TMJ imaging with an 8-channel surface coil. Group C (29 female, 11male, median age 22.5 years old) underwent single-channel surface coil imaging. There were no significant differences in age, gender, type or disease types among groups (0.05). Six healthy volunteers without TMD (4 female, 2 male, range 19 to 45 years old) underwent imaging with all three coils as self-control. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and image quality were compared for five regions of interest (ROI) in both patients and volunteers. Under the same sequence and the same parameters, SNR and CNR in group B were higher than those in group A, and SNR and CNR in group C were also higher than those in group A, the differences were statistically significant (0.05). However, there were significant differences in SNR and CNR between group B and group C in the closed and open positions of ROI1, the open positions of ROI3 and the open positions of ROI5 (0.05), and there were no significant differences in other positions (0.05). Group B had the best image quality, followed by group C and group A had the worst image quality. There were significant differences in the visualization of OSag PDWI in the closed mouth position, OCor T2WI in the coronal position, and OSag PDWI in the open mouth position, such as condyle, anterior attachment, joint disc, double lamina area, joint cavity and lateral pterygoid muscle (0.05). There were significant differences between group B and group C in showing the joint cavity in the closed mouth position and showing the structure of the bilaminar area in the open mouth position (0.05). There was no significant difference in other regions of interest (0.05). The subjective scores of condyle, anterior attachment, articular disc, bilaminar area, articular cavity, lateral pterygos muscle and other structures were medium to high in group A, high in group B, and high or high in group C by two radiologists independently. In the five rois, the 8-channel TMJ surface coil showed more details, especially in the articular disc, condyle and lateral pterygoid muscle regions, and had more advantages in both volunteers and patients. The 8-channel TMJ-specific surface coil provides significantly clearer visualization of critical anatomical details within the ROIs, demonstrating the highest clinical application value and is recommended as the preferred choice.

Download full-text PDF

Source
http://dx.doi.org/10.3760/cma.j.cn112144-20250411-00132DOI Listing

Publication Analysis

Top Keywords

surface coil
24
group
18
osag pdwi
16
group group
16
years underwent
16
mouth position
16
weighted imaging
12
median age
12
image quality
12
snr cnr
12

Similar Publications

RNA G-quadruplexes (rG4s) are emerging as vital structural elements involved in processes like gene regulation, translation, and genome stability. Found in untranslated regions of messenger RNAs (mRNAs), they influence translation efficiency and mRNA localization. Additionally, rG4s of long noncoding RNAs and telomeric RNA play roles in RNA processing and cellular aging.

View Article and Find Full Text PDF

Purpose: To objectively quantify, in East Asians and Caucasians, the width and distribution of the retro-orbicularis oculi and frontalis fat (ROOF) pad, subcutaneous fat, and orbicularis oculi muscle (OOM) at the superior orbital rim margin as well as 5 mm superior and inferior to this point.

Methods: Thirty adults were studied by high-resolution, surface coil MRI. In the quasi-sagittal image through the globe center, the ROOF, subcutaneous fat, and OOM thickness were measured anterior to the orbital septum, at 3 points: at the superior orbital rim, and 5 mm superior, and 5 mm inferior to the rim.

View Article and Find Full Text PDF

Kinesin-8 motors regulate kinetochore-microtubule dynamics and control spindle length and positioning. Certain isoforms achieve this by traversing microtubules, accumulating at plus-ends, and depolymerizing terminal αβ-tubulin subunits. While the kinesin-8 motor domain is well characterized, the tail domain regions are less understood.

View Article and Find Full Text PDF

Comparative analysis of CDR3 length-dependent patterns in VHHs.

Front Immunol

September 2025

Drug Discovery and Development, Chantibody Therapeutics, Menlo Park, CA, United States.

Introduction: VHHs, or nanobodies, are distinguished by their compact size, high stability, and unique ability to selectively target specific epitopes. The CDR3 region in VHHs, which plays a crucial role in antigen binding, exhibits significant diversity and varies among species.

Method: This study systematically examined CDR3 length dependent patterns by analyzing NGS sequences from the PBMCs of Alpacas, Llamas and Bactrians, in conjunction with VHH structure data from the public database.

View Article and Find Full Text PDF

This study presents the design, simulation, and experimental validation of a novel multimodal concentric surface coil for MR imaging, developed to achieve higher B1 field efficiency while maintaining low SAR for enhanced imaging performance. The coil comprises multiple electromagnetically coupled concentric resonators of varying sizes. The resonant frequency of a desired mode is tuned to 127 MHz, as an example, to demonstrate the performance of the proposed technique at 3 Tesla.

View Article and Find Full Text PDF