A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

In situ self-growth nano-selenium hydrogel coating alleviates surface thrombosis of blood-contacting devices by inactivating inflammatory cells. | LitMetric

In situ self-growth nano-selenium hydrogel coating alleviates surface thrombosis of blood-contacting devices by inactivating inflammatory cells.

Biomaterials

National Engineering Research Center for Biomaterials, College of Biomedical Engineering, Sichuan University, Chengdu, 610064, China; Research Unit of Minimally Invasive Treatment of Structural Heart Disease, Chinese Academy of Medical Sciences, Beijing, 100700, China. Electronic address: yunbing.wa

Published: January 2026


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The formation of thrombi in blood-contacting devices is accompanied by a several risks that can be life-threatening. Specifically, the process of blood exposure immediately after implantation triggers an immune response aimed at removing foreign substances, which can lead to thrombosis, inflammation and device malfunction. To confer anticoagulant properties to the implanted devices, a nano-selenium hydrogel coating which was in-situ self-growing on implant devices had been developed that inhibited thrombosis by intervening in the inflammatory cell activation pathway, possibly by decreasing tissue factor activity and thrombin production expressed by inflammatory cells. Compared with the selenium-free coating, the nano-selenium hydrogel coating significantly inhibited macrophage activation, as demonstrated by reduced M1 phenotype and increased M2 phenotype polarization, resulting in a 146 % increase in the M2/M1 ratio, together with the reduction of secretion of pro-inflammatory cytokines. More importantly, the selenium coating reduced macrophage procoagulant activity through macrophage inactivation, resulting in decreased tissue factor (TF) release and thrombin production. Remarkably, the coating suppressed the coagulation response in a rabbit model of LPS-induced inflammation and in patients with clinical sepsis, thereby reducing thrombus formation manifested by decreased fibrin deposition and reduced monocyte markers. Further studies demonstrated that coated central venous catheters (CVCs) in rabbit and pig vascular models diminished thrombosis and vascular inflammatory activation. Overall, this active anti-inflammatory hydrogel coating strategy is effective in inhibiting thrombus formation on blood-contacting device surfaces, especially in more challenging bloodstream environments.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.biomaterials.2025.123519DOI Listing

Publication Analysis

Top Keywords

hydrogel coating
16
nano-selenium hydrogel
12
blood-contacting devices
8
inflammatory cells
8
tissue factor
8
thrombin production
8
thrombus formation
8
coating
7
situ self-growth
4
self-growth nano-selenium
4

Similar Publications