Article Abstract

: Aortic stenosis (AS) leads to progressive left ventricular (LV) dysfunction, making early detection crucial. Global longitudinal strain (GLS) is an echocardiographic marker of subclinical LV dysfunction; however, echocardiography has limitations, including operator dependency and acoustic variability. Cardiac magnetic resonance (CMR) is a valuable complementary tool, and artificial intelligence (AI) may enhance strain measurement accuracy, though its role in AS remains underexplored. To evaluate the performance of an AI-based CMR feature tracking tool for the assessment of LV global and segmental GLS in AS patients and compare results with the respective measurements from healthy volunteers (control group), as well as with the GLS obtained using the echocardiographic speckle tracking technique. : This retrospective study analysed 111 CMR exams (70 AS patients, 41 healthy controls) from a single centre. AI-derived GLS values from gradient echo 2-, 3-, and 4-chamber CMR views were manually reviewed for accuracy. Error rates, segmental, and global myocardial strain differences were assessed between AS patients and the control group. : AI-based CMR GLS strongly correlated with echocardiographic GLS (r = 0.694, < 0.001) and showed lower variability. The AI-derived GLS from CMR was significantly lower in aortic stenosis patients compared to controls (-17.86 ± 3.47 vs. -20.70 ± 1.98). However, AI-based strain analysis had an overall error rate of 6%, which was significantly higher in AS patients (18.6%) compared to healthy controls (2.44%) ( = 0.0088). The 3-chamber CMR view was the most error-prone (50% of isolated errors). Segmental strain variability between AS patients and controls was most pronounced in basal segments, with smaller differences in middle and apical segments. CMR demonstrated greater precision than echocardiography, as indicated by a smaller standard deviation in GLS measurements (3.47 vs. 4.98). : The AI-based CMR feature tracking technique provides accurate and reproducible GLS measurements, showing strong agreement with echocardiographic speckle tracking-based GLS. However, the higher error rates in AS patients compared to controls underscore the need for more advanced AI algorithms to improve performance in cardiac pathology.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12194916PMC
http://dx.doi.org/10.3390/medicina61060950DOI Listing

Publication Analysis

Top Keywords

aortic stenosis
12
healthy controls
12
ai-based cmr
12
gls
10
cmr
9
artificial intelligence
8
performance cardiac
8
cardiac magnetic
8
magnetic resonance
8
strain analysis
8

Similar Publications

Clinical outcomes following TAVR for patients with low and very low gradient aortic stenosis.

Prog Cardiovasc Dis

September 2025

Department of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, OH, USA. Electronic address:

Objectives: This study explores the impact of lower baseline aortic valve (AV) mean gradients on the clinical outcomes of patients with low-gradient aortic stenosis (LG AS) post-transcatheter aortic valve replacement (TAVR). Additionally, the study aims to understand the predictors of a lower baseline AV mean gradient (MG).

Background: Reduced left ventricular ejection fraction (LVEF) and low-flow states are known to correlate with worse clinical outcomes.

View Article and Find Full Text PDF

Comparison of short- and long-term outcomes between transcatheter and surgical aortic valve replacement for bicuspid aortic valve stenosis: a systematic review and meta-analysis.

Int J Surg

September 2025

Department of Cardiovascular Surgery, The Affiliated Hospital, Southwest Medical University, Metabolic Vascular Diseases Key Laboratory of Sichuan Province, Key Laboratory of Cardiovascular Remodeling and Dysfunction, Luzhou, Sichuan, PR China.

Objective: This meta-analysis aimed to compare the perioperative safety and efficacy of transcatheter aortic valve replacement (TAVR) versus surgical aortic valve replacement (SAVR) in bicuspid aortic valve (BAV) stenosis.

Methods: We systematically analyzed studies from PubMed, Cochrane Library, Embase, and CNKI comparing TAVR and SAVR in BAV stenosis. Outcomes included postoperative mortality, complications, all-cause survival, and freedom from stroke.

View Article and Find Full Text PDF

Hypertrophic Cardiomyopathy: Mechanisms of Pathogenicity.

Biomed Environ Sci

August 2025

Department of Cardiology, Fuwai Central China Cardiovascular Hospital, Henan Provincial People's Hospital Heart Center, Zhengzhou 451464, Henan, China.

Hypertrophic cardiomyopathy (HCM) is a major contributor to cardiovascular diseases (CVD), the leading cause of death globally. HCM can precipitate heart failure (HF) by causing the cardiac tissue to weaken and stretch, thereby impairing its pumping efficiency. Moreover, HCM increases the risk of atrial fibrillation, which in turn elevates the likelihood of thrombus formation and stroke.

View Article and Find Full Text PDF