A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

LSPR-Driven Dual-Mode Urea Sensor for Milk Adulteration Detection Using Gold Nanobipyramids and Upconversion Nanoparticles. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Ensuring food quality and safety is crucial, as the consumption of contaminated or substandard food poses serious risks to public health and imposes a substantial economic burden. Among various food safety concerns, milk adulteration with urea has emerged as a significant issue. This study presents a highly sensitive dual-mode colorimetric and fluorometric urea sensor for milk adulteration detection, utilizing enzymatic hydrolysis with Fenton-mediated plasmonic etching. The urease-catalyzed hydrolysis of urea produces ammonia, which inhibits the Fenton reaction, thereby modulating the localized surface plasmon resonance (LSPR) of gold nanobipyramids (AuNBPs). The resulting LSPR shift (Δλ > 150 nm) generates a distinct colorimetric response across a broad urea concentration range (0-5 mM), with a low limit of detection (LoD) of 0.09 μM. Moreover, the tunable LSPR of AuNBPs serves as a dynamic quencher for upconversion nanoparticles (UCNPs) via Förster resonance energy transfer (FRET), enabling ratiometric fluorometric sensing with high sensitivity (LoD of 0.056 μM). The spectral overlap between the LSPR of AuNBPs and the green/red emission of UCNPs facilitates a dynamic "Off/On-On/Off" response, ensuring accurate urea quantification in fluorescence mode. Furthermore, a smartphone-based RGB analysis enhances accessibility for on-site monitoring of urea levels, making this sensor a promising tool for real-world applications.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acssensors.5c01527DOI Listing

Publication Analysis

Top Keywords

milk adulteration
12
urea sensor
8
sensor milk
8
adulteration detection
8
gold nanobipyramids
8
upconversion nanoparticles
8
lspr aunbps
8
urea
7
lspr-driven dual-mode
4
dual-mode urea
4

Similar Publications