A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Multimodal in vitro characterization techniques for assessing the adhesion of transdermal patches: A proof-of-concept study. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Adhesion is a critical factor in determining the quality, efficacy, and safety of transdermal patches. The adhesive properties directly influence drug permeation and flux, especially for matrix system patches. For potent therapeutics, the strength of adhesion and any minor tampering during wear can significantly impact the patch's in vivo performance. Adhesive properties can vary over time due to changes in polymer interactions, with storage-induced three-dimensional alterations potentially affecting both adhesive strength and drug characteristics. Despite these complexities, no standardized method currently exists for measuring adhesive strength in transdermal patches. Therefore, reliable and consistent testing methods are essential to ensure patch quality and therapeutic efficacy. This study presents a multimodal approach to assess the adhesion of transdermal patches, incorporating traditional probe-tack and in vitro permeation tests, along with innovative techniques such as interferometry for surface topography analysis and infrared thermography to evaluate structural and adhesive deficiencies. The feasibility of these methods was validated by tampering fresh and expired patches across multiple rounds (2R, 5R, 10R). Validation was confirmed by measuring patch thickness before and after tampering with digital calipers, quantifying removed drug, and analyzing patch roughness and topography via interferometry. Adhesive performance was further assessed using the probe-tack test, while nicotine permeation profiles (both intact and tampered) were evaluated using vertical Franz diffusion cells. Statistical analysis, including one-way ANOVA and Tukey's post-hoc test, identified significant differences between the datasets. The study utilized two different brands of 14 mg nicotine patches as models. Results indicated that the reference patches exhibited superior adhesive performance and uniform distribution compared to the test patches. The data demonstrates the potential of thermal imaging and interferometry as complementary techniques to distinguish adhesive performance differences in Q2-equivalent transdermal patches produced by different manufacturers.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejpb.2025.114783DOI Listing

Publication Analysis

Top Keywords

transdermal patches
20
adhesive performance
12
patches
10
adhesion transdermal
8
adhesive
8
adhesive properties
8
adhesive strength
8
transdermal
5
multimodal vitro
4
vitro characterization
4

Similar Publications