Article Abstract

Objectives: This practice parameter was revised collaboratively by the American College of Radiology (ACR), and American Radium Society (ARS). Image-guided radiation therapy (IGRT) uses various imaging modalities to maximize the accuracy and precision of radiation treatment delivery.

Methods: This practice parameter was developed according to the process described under the heading The Process for Developing ACR Practice Parameters and Technical Standards on the ACR website (https://www.acr.org/Clinical-Resources/Practice-Parameters-and-Technical-Standards) by the Committee on Practice Parameters-Radiation Oncology of the ACR Commission on Radiation Oncology in collaboration with the ARS.

Results: This practice parameter for IGRT addresses qualifications and responsibilities of personnel, clinical IGRT implementation, documentation, quality control and improvement, safety, and patient education. Since the publication of the ACR-ASTRO Practice Parameter in 2019, there is now more clarity as to what criteria and parameters need to be documented in the medical record, a better appreciation of the large amount of imaging data, how to interpret such data, as well as the complex interactions of multiple systems in the implementation of IGRT.

Conclusions: This practice parameter assists practitioners in the clinical use of IGRT. IGRT should complement and be used in combination with other quality assurance processes. IGRT is a rapidly evolving field, and practitioners should have a thorough understanding of its strengths and potential limitations.

Download full-text PDF

Source
http://dx.doi.org/10.1097/COC.0000000000001220DOI Listing

Publication Analysis

Top Keywords

practice parameter
24
image-guided radiation
8
radiation therapy
8
therapy igrt
8
clinical igrt
8
igrt
7
practice
7
parameter
6
acr-ars practice
4
parameter image-guided
4

Similar Publications

Background: Severe acute pancreatitis (SAP) is a life-threatening condition requiring early risk stratification. While the Bedside Index for Severity in Acute Pancreatitis (BISAP) is widely used, its reliance on complex parameters limits its applicability in resource-constrained settings. This study introduces a decision tree model based on Classification and Regression Tree (CART) analysis, utilizing Neutrophil-to-Lymphocyte Ratio (NLR) and C-reactive Protein (CRP), as a simpler alternative for early SAP prediction.

View Article and Find Full Text PDF

Accurate prediction of time-varying dynamic parameters during the milling process is a prerequisite for chatter-free cutting of thin-walled parts. In this paper, a matrix iterative prediction method based on weighted parameters is proposed for the time-varying structural modes during the milling of thin-walled blade structures. The thin-walled blade finite element model is established based on the 4-node plate element, and the time-varying dynamic parameters of the workpiece during the cutting process can be obtained by modifying the thickness of the nodes through the constructed mesh element finite element model It is not necessary to re-divide the mesh elements of the thin-walled parts at each cutting position, thus improving the calculation efficiency of the dynamic parameters of the workpiece.

View Article and Find Full Text PDF

Volumetric modulated arc therapy (VMAT) for lung cancer involves complex multileaf collimator (MLC) motion, which increases sensitivity to interplay effects with tumour motion. Current dynamic conformal arc methods address this issue but may limit the achievable dose distribution optimisation compared with standard VMAT. This study examined the clinical utility of a VMAT technique with monitor unit limits (VMATliMU) to mimic conformal arc delivery and reduce interplay effects while maintaining plan quality.

View Article and Find Full Text PDF

Background: Ventral hernias, particularly umbilical hernias, are the second most common type of abdominal wall hernias after inguinal hernias. Surgical intervention using mesh placement has become standard due to its effectiveness in reducing recurrence. Among mesh techniques, the sublay approach is widely practiced through both open and laparoscopic methods.

View Article and Find Full Text PDF

Estimating statistical power is essential for designing behavioral medicine studies efficiently and conserving finite resources. Sometimes behavioral medicine researchers are interested in calculating power for 1-sided z-tests of individual parameters (e.g.

View Article and Find Full Text PDF