Article Abstract

Transcatheter aortic valve replacement has emerged as a valuable alternative to surgical aortic valve replacement in patients with severe aortic stenosis. Given the expansion of transcatheter aortic valve replacement to lower-risk and younger populations with longer life expectancy, the durability of transcatheter heart valves (THVs) has become an important issue that may impact cardiovascular outcomes. THVs share similarities with surgical valves but have unique features, including a trend to larger effective orifice area and less prosthesis-patient mismatch, interactions with the native valve, and crimping process, that may all potentially influence a THV's life span. Multiple mechanisms may lead to bioprosthetic valve dysfunction, including structural valve deterioration, thrombosis, endocarditis, and nonstructural valve deterioration. With an incidence of up to 12.3% 5 years after transcatheter aortic valve replacement, structural valve deterioration represents the ultimate consequence of fibrotic remodeling and calcification within the bioprosthesis, driven by thrombotic and inflammatory processes involving the native aortic valve and influenced by patient and procedural factors. Understanding these mechanisms is crucial for improving THV durability.

Download full-text PDF

Source
http://dx.doi.org/10.1161/JAHA.125.041505DOI Listing

Publication Analysis

Top Keywords

aortic valve
24
transcatheter aortic
16
valve deterioration
16
valve replacement
16
valve
12
structural valve
12
aortic
6
transcatheter
5
valve durability
4
durability focus
4

Similar Publications

Comparison of short- and long-term outcomes between transcatheter and surgical aortic valve replacement for bicuspid aortic valve stenosis: a systematic review and meta-analysis.

Int J Surg

September 2025

Department of Cardiovascular Surgery, The Affiliated Hospital, Southwest Medical University, Metabolic Vascular Diseases Key Laboratory of Sichuan Province, Key Laboratory of Cardiovascular Remodeling and Dysfunction, Luzhou, Sichuan, PR China.

Objective: This meta-analysis aimed to compare the perioperative safety and efficacy of transcatheter aortic valve replacement (TAVR) versus surgical aortic valve replacement (SAVR) in bicuspid aortic valve (BAV) stenosis.

Methods: We systematically analyzed studies from PubMed, Cochrane Library, Embase, and CNKI comparing TAVR and SAVR in BAV stenosis. Outcomes included postoperative mortality, complications, all-cause survival, and freedom from stroke.

View Article and Find Full Text PDF

Paraprosthetic Leakage and Infection Two Years after the Konno Procedure: A Case Report.

Kardiologiia

September 2025

West China Hospital of Sichuan University, Department of Cardiovascular Surgery, Sichuan University.

A middle-aged female presenting with progressive heart failure was admitted to the emergency department. She had a history of mitral and aortic valve replacement and a reoperation involving the Konno procedure. Echocardiography suggested a possible paraprosthetic leakage, which was confirmed during surgery.

View Article and Find Full Text PDF

Background: Mitral regurgitation (MR) may rarely worsen after transcatheter aortic valve implantation (TAVI) due to mechanical interference from the transcatheter heart valve (THV). Standard surgical approaches in these cases are often challenging due to anatomical constraints. Thus, there is a need for the development of effective alternatives to address this issue.

View Article and Find Full Text PDF

Rapid Atrial Pacing After TAVI for Pacemaker Prediction.

Rev Cardiovasc Med

August 2025

Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel, European Reference Networks Guard-Heart, 1090 Brussels, Belgium.

Despite continued advancements in transcatheter aortic valve implantation (TAVI) techniques, the incidence of permanent pacemaker implantation (PPI) remains substantial. Established predictors of PPI include advanced age, pre-existing electrocardiographic conduction abnormalities, prosthetic valve type, implantation depth, and anatomical parameters, such as membranous septum length, which are currently under active investigation. In routine clinical practice, the management strategy often involves the temporary placement of a transvenous pacemaker lead, followed by a period of observation.

View Article and Find Full Text PDF

Background: Differences between female and male patients may influence the outcomes of transcatheter aortic valve replacement (TAVR). However, knowledge regarding known sex differences in TAVR procedures among Chinese people remains limited. Therefore, this study aimed to investigate the impact of sex-related differences on reverse left ventricular (LV) remodeling following TAVR in the Chinese population.

View Article and Find Full Text PDF