Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

: Background: Allograft rejection remains a major barrier to the long-term success of organ transplantation. The current gold standard for diagnosis-tissue biopsy is invasive and carries inherent risks, including sampling errors, procedural complications, and high costs. There is a pressing need for an efficient, non-invasive strategy for the early detection and monitoring of transplant rejection. Methods: We developed a macrophage-targeted, activatable imaging probe () by encapsulating the H₂O₂-responsive aggregation-induced emission (AIE) molecule into glucan particles (GPs) via electrostatic and hydrophobic interactions. The probe's responsiveness to H₂O₂ was characterized using UV-vis and fluorescence spectroscopy. Biocompatibility was evaluated through hemolysis assays, immunogenicity testing, biochemical analysis, and histopathology. Macrophage polarization and probe specificity were assessed using confocal laser scanning microscopy (CLSM), flow cytometry (FCM), and ELISA. A murine dorsal skin transplantation model was established to dynamically monitor graft rejection and the therapeutic efficacy of FK506, using fluorescence imaging at postoperative days (POD) 1, 3, 5, and 7. Pathological validation was performed via H&E staining and immunofluorescence. Results: exhibited excellent biosafety, with low cytotoxicity, minimal hemolytic activity, low immunogenicity, and negligible organ toxicity. Upon oral administration, the fluorescence signal of was selectively activated by M1 macrophages, enabling early and sensitive detection of transplant rejection. Moreover, a single oral dose allowed real-time tracking of immunosuppressive therapy with FK506 Conclusion: represent a promising non-invasive platform for early diagnosis and longitudinal monitoring of transplant rejection and therapeutic response, with strong translational potential in solid organ transplantation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12160014PMC
http://dx.doi.org/10.7150/thno.110866DOI Listing

Publication Analysis

Top Keywords

transplant rejection
12
aggregation-induced emission
8
allograft rejection
8
organ transplantation
8
monitoring transplant
8
rejection therapeutic
8
rejection
6
activatable biomimetic
4
biomimetic probe
4
probe aggregation-induced
4

Similar Publications

Eplet mismatch analysis in kidney transplantation: from concept to clinical practice.

Clin Transplant Res

September 2025

Department of Laboratory Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.

Eplet mismatch analysis offers a refined approach to assessing donor-recipient compatibility in kidney transplantation, surpassing conventional antigen-level human leukocyte antigen (HLA) matching in predicting immunologic outcomes. By identifying polymorphic amino acid residues on HLA molecules recognized by B cell receptors, this method quantifies immunologic risk. Clinical studies demonstrate that high eplet mismatch loads, particularly at HLA-DQ, are strongly associated with donor-specific antibody development, antibody-mediated rejection, and reduced graft survival.

View Article and Find Full Text PDF

Introduction: Liver transplantation is associated with various metabolic disorders. Peri-transplant hyperglycemia is among the most frequent metabolic disorders among liver transplant recipients. Hyperglycemia following liver transplantation can increase the risk of post-transplant complications, potentially impacting both graft and recipient outcomes.

View Article and Find Full Text PDF

Timely diagnosing and monitoring of primary graft dysfunction is pivotal for heart transplant patient surveillance. Transthoracic echocardiography is the primary noninvasive method for follow-up of heart transplant recipients, which provides comprehensive information on cardiac morphology and function. It is a sensitive tool in diagnosing rejection, helping to improve therapeutic approaches for this condition, and monitoring cardiac function during therapy.

View Article and Find Full Text PDF

Glanzmann thrombasthenia (GT) is a rare autosomal recessive platelet disorder characterized by abnormalities in platelet aggregation, resulting from quantitative or qualitative defects in integrins αIIb and β3. Currently, allogeneic hematopoietic stem cell transplantation (allo-HSCT) is the only potentially curative therapeutic approach for severe GT. In this report, we present 2 children with GT that underwent successful allo-HSCT, along with 2008 to 2022 data from the Center for International Blood and Marrow Transplant Research and a summary of the existing literature providing further evidence that allo-HSCT can be a curative approach that prevents severe and life-threatening bleeding in GT.

View Article and Find Full Text PDF

Introduction: Differentiating acute tubular necrosis (ATN) from rejection in pediatric kidney transplant (KT) recipients remains challenging and necessitates invasive biopsy. Doppler ultrasound-derived resistive index (RI) is a noninvasive modality to assess graft status, but its diagnostic utility in children is unclear. This study evaluates RI's ability to distinguish ATN and rejection in KT.

View Article and Find Full Text PDF