98%
921
2 minutes
20
Endovascular treatments in emergency or bailout situations focusing on anatomical regions with high extension and flexion movement remain a key area of interest. To date, the main field of application of the GORE VIABAHN VBX Balloon Expandable Endoprosthesis (VBX) (Gore, USA) has been in complex iliac occlusions and aortic pathologies. This retrospective study aimed to assess the safety and effectiveness of the VBX in a real-world patient population at a single centre, focusing on anatomical regions under high mechanical stress. This study presents the first data set for the VBX beyond its use in aortic and iliac pathologies. In this retrospective monocentric study, all patients included had a Gore Viabahn balloon expandable (VBX) implanted at a tertiary referral hospital during the observation period 02/2020 to 03/2024. The median population age was 69 years, and eight patients were female. The mean Body Mass Index was 26,2±4,9 kg/m. Eleven patients were treated in the inguinal region, nine in the shoulder region, and two in the knee region. The most common indications for implantation were stenosis (9/21) and bleeding (6/18). Eleven patients had an urgent need for implantation. Technical success was 100%. No stent-associated complication was observed. The 30-day mortality rate was 0%. The median follow-up time for all patients was 230 days (27-1064 d). Primary patency for all patients was 95,2%, while secondary patency was 100%. The VBX represents a safe and easy-to-use stent graft for managing complications, even in challenging anatomy regions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1024/0301-1526/a001206 | DOI Listing |
Ther Adv Cardiovasc Dis
August 2025
Department of Neurosurgery, Osaka Red Cross Hospital, Osaka, Japan.
Carotid blowout syndrome (CBS) is a potentially fatal condition requiring prompt diagnosis and intervention. CBS primarily affects patients with a history of surgery or irradiation for head and neck malignancies. In this report, we describe a case of CBS in which the carotid artery ruptured 2 months after carotid artery stenting in a patient with a previous history of surgery and irradiation for pharyngeal cancer.
View Article and Find Full Text PDFVasa
June 2025
Vascular Surgery, Medical Faculty, University of Augsburg, Germany.
Endovascular treatments in emergency or bailout situations focusing on anatomical regions with high extension and flexion movement remain a key area of interest. To date, the main field of application of the GORE VIABAHN VBX Balloon Expandable Endoprosthesis (VBX) (Gore, USA) has been in complex iliac occlusions and aortic pathologies. This retrospective study aimed to assess the safety and effectiveness of the VBX in a real-world patient population at a single centre, focusing on anatomical regions under high mechanical stress.
View Article and Find Full Text PDFVasc Endovascular Surg
August 2025
Angiology and Vascular Surgery Department, Valladolid University Hospital, Valladolid, Spain.
This case report aims to present a new endovascular technique for arterial embolization using a relatively recently developed endovascular device, Shape Memory Polymer (SMP) Embolization Plug (IMPEDE, Shape Memory Medical). A 66-year-old man presented an asymptomatic common iliac aneurysm with a maximun diameter of 4.4 cm and a previous aorto-bifemoral bypass.
View Article and Find Full Text PDFJ Endovasc Ther
April 2025
Department of Vascular and Endovascular Surgery, Paris Saint Joseph Hospital Group, Paris, France.
Purpose: The performance of self-expanding stent graft (Gore Viabahn) in femoropopliteal interventions has been proven through trials with long lesions. However, there are limited data on the incorporation of additional edge-protection to reduce focal edge stenosis. The aim of this study was to assess the clinical safety and efficiency of Viabahn stent graft incorporating additional edge-protection in the treatment of long femoropopliteal lesions [TransAtlantic Inter-Society Consensus (TASC) C/D] in patients with symptomatic peripheral arterial disease.
View Article and Find Full Text PDFJ Endovasc Ther
April 2025
Vascular Surgery Department, Norfolk and Norwich University Hospital, Norwich, UK.
Background: Malposition of central venous catheter is a notable technical complication and often need retrieval to avoid further complications. We present a retrospective assessment of case series and literature review of the safety and efficacy of open and endovascular procedures performed to retrieve malpositioned central venous catheters in the subclavian artery.
Data Sources: PubMed/Medline, Ovid and Embase.