Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Purpose: The aim of this study is to develop a predictive model for the therapeutic efficacy of high-intensity focused ultrasound (HIFU) ablation in the treatment of adenomyosis, utilizing dual-sequence MRI radiomics.
Methods: A retrospective analysis was conducted on 114 patients diagnosed with adenomyosis who underwent ultrasound-guided HIFU ablation under conscious sedation between July 2021 and July 2023. Patients were randomly allocated into a training set and a test set at a ratio of 7:3. The study aimed to evaluate the distribution of clinical characteristics among patients experiencing effective versus ineffective ablation at two distinct classification thresholds (0.7 and 0.5). Multiple models were developed to explore the combination of effective radiomic features derived from dual-sequence MRI and clinical data. Radiomic features were extracted from the MRI images of adenomyosis lesions in the training set. This process included feature extraction, selection, model construction, and evaluation. Logistic regression was used to construct the predictive model, and its performance was assessed on the test set using the receiver operating characteristic (ROC) curve. The Delong test, net reclassification improvement (NRI), and integrated discrimination improvement (IDI) were used to compare the predictive accuracy of the models.
Results: The predictive model showed better alignment with actual ablation outcomes, particularly for predicting ablation success rates exceeding 50%. The combination of radiomic features from the two MRI sequences achieved an AUC of 0.84 in the test set. Decision curve analysis demonstrated that the combined model provided greater net benefit than the single-sequence radiomics model across a broader range of risk thresholds. For the prediction of 70% efficacy, the combined model achieved an AUC of 0.804 in the test set, slightly lower the 50% efficacy prediction task.
Conclusion: The model, based on dual-sequence MRI radiomics, emerges as a promising tool for predicting the efficacy of HIFU ablation, potentially aiding clinicians in anticipating the outcomes of HIFU ablation procedures.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12075450 | PMC |
http://dx.doi.org/10.2147/IJWH.S512216 | DOI Listing |