98%
921
2 minutes
20
Background And Purpose: CTP Software packages utilise various mathematical techniques to transform source data into clinically useful maps. These techniques have not been validated for Posterior circulation infarction (POCI). Studies of anterior circulation stroke have shown that algorithm differences significantly influence the accuracy and best tissue parameters and thresholds of output maps. We examined the influence of the processing algorithm on CTP accuracy and best tissue parameters and thresholds in acute POCI.
Materials And Methods: Data were analysed from patients diagnosed with a POCI enrolled in the International-stroke-perfusionimaging-registry (INSPIRE). Fifty-eight-patients with baseline multimodal-CT with occlusion of a large posterior-circulation artery and follow up diffusion-weighted-MRI at 24-48 hours were included. CTP parametric maps were generated using five algorithms; Singular value deconvolution, Singular value deconvolution with delay and dispersion correction (SVDd), Partial-deconvolution, Stroke-stenosis and Maximum Slope models. Receiver operating curve (ROC) analysis and linear regression were used for voxel-based analysis and volume-based analysis respectively.
Results: Partial-deconvolution using the Mean Transit Time (MTT) parameter was the optimal technique for characterising ischaemic-penumbra (AUC=0.73 [0.64-0.81]) and infarct-core (AUC=0.70 [0.63-0.73]). The optimal MTT threshold was >165% and >180% for core and penumbra respectively. The optimal MTT threshold was >165% and >180% for core and penumbra respectively. By volume analysis; the SVDd and Maximum Slope (MS) using MTT were the best algorithms for estimation of penumbra and core respectively. Estimates of core volume were weak (all R<0.02). Processing algorithm influenced model accuracy (AUC-range: 0.700.73 [core], 0.67-0.72 [penumbra]) and optimal tissue parameter and threshold. MTT was the most consistent optimal parameter across algorithms. The optimal MTT threshold varied from >120% to >200% for core and 155% to 195% for penumbra.
Conclusions: CTP has diagnostic utility in POCI. There were notable differences in optimal parameter and threshold by algorithm. Clinicians should be aware of the specific algorithm used in their CTP processing software and apply caution when comparing output maps between vendors.
Abbreviations: CTP = CT Perfusion; POCI = Posterior circulation infarction, ACS = Anterior circulation stroke, ROC = Reciever operating curve, AUC = Area under the curve, SVD = Singular value deconvolution, SVDd = Singular value deconvolution with delay and dispersion correction, MTT = Mean transit Time, TTP = Time to Peak, DT = Delay time, TMax = Time to maximum of the tissue resiude curve, CBV = Cerebral blood volume, CBF = Cerebral blood flow, AIF = Arterial input function, VOF = Venous output function, EVT = endovascular thrombectomy, mRS = modified rankin score, LKW = Last known well, MVD = mean volumetric difference.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3174/ajnr.A8833 | DOI Listing |
Med Phys
July 2025
Department of Biomedical Engineering, University at Buffalo, Buffalo, New York, USA.
Background: In neurovascular disease applications, 2D quantitative angiography (QA) based on digital subtraction angiography (DSA), is an intraoperative methodology used to assess disease severity and guide treatment. However, despite DSA's ability to produce detailed 2D projection images, the inherent dynamic 3D nature of blood flow and its temporal aspects can distort key hemodynamic parameters when reduced to 2D. This distortion is primarily due to biases such as projection-induced foreshortening and variability from manual contrast injection.
View Article and Find Full Text PDFAJNR Am J Neuroradiol
May 2025
From the Liverpool Hospital, Liverpool, New South Wales, Australia, Department of Neurology and Neurophysiology (L.S.E., C.CS., D.C., L.L., M.W.P) South Western Sydney Clinical School, UNSW (L.S.E., C.CS., D.C., L.L., C.C., M.W.P) and Ingham Institute for Applied Medical Research, Sydney (L.S.E., C.
Background And Purpose: CTP Software packages utilise various mathematical techniques to transform source data into clinically useful maps. These techniques have not been validated for Posterior circulation infarction (POCI). Studies of anterior circulation stroke have shown that algorithm differences significantly influence the accuracy and best tissue parameters and thresholds of output maps.
View Article and Find Full Text PDFMath Biosci Eng
March 2025
Department of Mathematics and Statistics, University of North Carolina at Charlotte, USA.
Performing complete deconvolution analysis for bulk RNA-seq data to obtain both cell type specific gene expression profiles (GEP) and relative cell abundances is a challenging task. One of the fundamental models used, the nonnegative matrix factorization (NMF), is mathematically ill-posed. Although several of complete deconvolution methods have been developed and their estimates compared to ground truth for some datasets appear promising, a comprehensive understanding of how to circumvent the ill-posedness and improve solution accuracy is still lacking.
View Article and Find Full Text PDFJ Chromatogr A
April 2025
Q-5 High Explosives Science and Technology, Los Alamos National Laboratory, Los Alamos, NM 87545, USA.
Non-targeted analysis of complex chemical mixtures can be difficult considering the convoluted nature of the matrix and the potential unknown chemical differences between samples or classes of samples. Ultrahigh pressure liquid chromatography coupled to quadrupole time-of-flight mass spectrometry (UHPLC-QTOF) is an ideal technique to probe chemical differences for a wide variety of samples. While UHPLC-QTOF can discover minute chemical differences down to low part per billion (ppb) concentrations with a high degree of confidence, the application of high-resolution mass spectrometry can yield massive amounts of information (∼ 10 gb per sample) that cannot be analyzed manually.
View Article and Find Full Text PDFLab Anim
April 2025
Cooperative Division of Veterinary Sciences, Tokyo University of Agriculture and Technology, Tokyo, Japan.
This study aimed to investigate the impact of selected analysis conditions on blood flow values and color maps in canine brain perfusion computed tomography (PCT) and to propose optimal analysis conditions. Dynamic computed tomography imaging was performed on six beagle dogs. Color maps were generated using a combination of analysis algorithms (box-modulation transfer function (Box-MTF) and singular value deconvolution plus (SVD+) methods), slice thicknesses (4.
View Article and Find Full Text PDF