A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Optic Nerve Sheath Diameter Estimation to Detect Increased Intracranial Pressure in Traumatic Brain Injury patients at a Level I Trauma Center in Eastern India. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: To evaluate the diagnostic accuracy of optic nerve sheath diameter (ONSD) measured by ultrasound as a non-invasive marker for detecting elevated intracranial pressure (ICP) in patients with traumatic brain injury (TBI), based on clinical and radiological findings.

Methods: This diagnostic accuracy study included 180 adult patients with isolated TBI admitted to a Level I Trauma Centre in Eastern India. ONSD was measured bilaterally using a 7.5 MHz linear ultrasound probe, 3 mm posterior to the globe. Clinical and radiological parameters were recorded, and increased ICP was determined based on a predefined clinical signs and computed tomography findings. Statistical analysis included logistic regression and receiver operating characteristic (ROC) curve analysis using Jamovi software.

Results: The mean ONSD was significantly higher in patients with increased ICP (5.36±0.56 mm) compared to those without (4.13±0.34 mm, <0.001). ROC analysis showed excellent diagnostic performance (area under the curve: 0.942), with sensitivity and specificity of 93.2% and 81.8%, respectively, at a cut-off value of 5.0 mm. The positive predictive value was 74.0%, and the negative predictive value was 99.0%. Increased ONSD was associated with TBI severity and poor Glasgow Outcome Scale scores at 3 months.

Conclusion: Ultrasound-measured ONSD is a sensitive, non-invasive bedside tool for detecting increased ICP in TBI patients, particularly useful in resource-limited settings.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12062819PMC
http://dx.doi.org/10.13004/kjnt.2025.21.e15DOI Listing

Publication Analysis

Top Keywords

optic nerve
8
nerve sheath
8
sheath diameter
8
intracranial pressure
8
traumatic brain
8
brain injury
8
level trauma
8
eastern india
8
diagnostic accuracy
8
onsd measured
8

Similar Publications